Is Duplex-Ultrasound a useful tool in defining rejection episodes in composite tissue allograft transplants?
Immunologic reactions in transplanted organs are in more or less all allograft patients detectable: clear parameters exist as e.g. in renal transplants where the clearance power reduces by rejection. On the contrary, in composite tissue allografts clear and objective indicators stating a rejection e...
Saved in:
Published in | Medical ultrasonography Vol. 17; no. 4; p. 550 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
Romania
Romanian Society of Ultrasonography in Medicine and Biology
01.12.2015
|
Subjects | |
Online Access | Get full text |
ISSN | 1844-4172 2066-8643 |
DOI | 10.11152/mu.2013.2066.174.dxu |
Cover
Summary: | Immunologic reactions in transplanted organs are in more or less all allograft patients detectable: clear parameters exist as e.g. in renal transplants where the clearance power reduces by rejection. On the contrary, in composite tissue allografts clear and objective indicators stating a rejection episode lack. We present the case of a hand-transplanted subject with signs of acute transplant rejection diagnosed by means of Duplex Ultrasound and confirmed by biopsy. |
---|---|
Bibliography: | SourceType-Scholarly Journals-1 ObjectType-General Information-1 content type line 14 |