Volume kinetic analysis of two crystalloid fluid bolus rates in anesthetized cats
Objective To investigate the volume kinetic between 2 crystalloid fluid bolus rates in anesthetized cats. Design Prospective, randomized, dose–response study. Setting University laboratory. Animals Ten convenience‐sample, purpose‐bred domestic shorthair and medium hair cats. Interventions Intravenou...
Saved in:
Published in | Journal of veterinary emergency and critical care (San Antonio, Tex. : 2000) Vol. 35; no. 1; pp. 41 - 51 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
United States
01.01.2025
|
Subjects | |
Online Access | Get full text |
ISSN | 1479-3261 1476-4431 1476-4431 |
DOI | 10.1111/vec.13449 |
Cover
Summary: | Objective
To investigate the volume kinetic between 2 crystalloid fluid bolus rates in anesthetized cats.
Design
Prospective, randomized, dose–response study.
Setting
University laboratory.
Animals
Ten convenience‐sample, purpose‐bred domestic shorthair and medium hair cats.
Interventions
Intravenous 20 mL/kg balanced crystalloid fluid over 10 (G10) or 40 (G40) minutes under anesthesia in a randomized order with at least a 5‐day washout period.
Measurements and Main Results
Serial measurements of hemoglobin (Hb) concentration and PCV were performed up to 60 minutes after conclusion of the fluid bolus. Plasma dilution was calculated with the Hb dilution method and fitted to a 2‐compartment microconstant kinetic model using nonlinear mixed‐effect models. The apparent central plasma volume (Vc) was similar between the 2 groups (G10: 81.2 ± 23.8 mL/kg and G40: 78.8 ± 10.2 mL/kg). The apparent peripheral volume (Vp) of G10 (4.81E+8 ± 2.66E+8 mL/kg) was twice that of G40 (2.36E+8 ± 6.44E+7 mL/kg). The rate constant from Vc to Vp (K12) of G10 (0.057 ± 0.0196/min) was almost twice that of G40 (0.0302 ± 0.00807/min). The elimination constant of G10 (0.0113 ± 0.00672/min) was almost twice that of G40 (0.00534 ± 0.00279/min). The peak plasma expansion was similar between G10 and G40 (20.7 ± 1.9 and 19.1 ± 5.1 mL/kg). Area under the curve for plasma dilution versus time of the first 90 minutes from the beginning of the boluses was not statistically different between G10 and G40.
Conclusions
The volume expansion over time was not different likely due to the slow elimination. The plasma dilution to crystalloid bolus between subjects is varied in anesthetized cats. Clinicians should consider the slow elimination and return of crystalloid fluid from the Vp to Vc when prescribing fluid therapy in anesthetized cats. |
---|---|
Bibliography: | Results of this study were presented as an abstract at the American College of Veterinary Anesthesia and Analgesia 2022 Annual Scientific Meeting. ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1479-3261 1476-4431 1476-4431 |