장수명주택 인필 벽체의 부착물에 대한 하중저항성에 대한 연구

Purpose: Recently, modular buildings, which can flexibly cope with changes due to remodeling and maintenance required for the physical durability of buildings and residential process, are receiving wide attention, and the industrialization house is differentiated from previous houses in such nature....

Full description

Saved in:
Bibliographic Details
Published inKIEAE Journal Vol. 18; no. 1; pp. 31 - 37
Main Authors 이종호(Lee, JongHo), 황은경(Hwang, Eun-Kyoung), 서동구(Seo, Dong-Goo), 김수암(Kim, Su-Am)
Format Journal Article
LanguageKorean
Published 한국생태환경건축학회 01.02.2018
Subjects
Online AccessGet full text
ISSN2288-968X
2288-9698
DOI10.12813/kieae.2018.18.1.031

Cover

More Information
Summary:Purpose: Recently, modular buildings, which can flexibly cope with changes due to remodeling and maintenance required for the physical durability of buildings and residential process, are receiving wide attention, and the industrialization house is differentiated from previous houses in such nature. When the residential space is composed of industrialization house, it is possible to compose the space in the form desired by the resident and such space can be modified at a desired period, thus it has greater significance in terms of variability. Therefore, it is necessary to identify problems when the industrialization house is installed on the housing and deduce improvement measures. Method: This study intends to carry out the improvement priority test for inhibitory factors of lightweight walls in an industrialization housing unit of a modular building, and confirm the performance level through a field test. The building used for the test was a two-story steel skeleton building and the testbed consisting of industrialization houses was established on the first floor for the test. The test result on the wall performance of installed industrialization house was drawn and compared with reference values for the purpose of institutionalization. Test method and evaluation standard were in accordance with ‘Improvement priority evaluation method for wall inhibitory factors (Architectural Institute of Korea).’ Results: The test result showed that the wall system using normal gypsum board was rated as grade 2 for horizontal and vertical pulling, and other wall systems were rated as grade 1. The ALC Block attachment method applied to the toilet system secured wall improvement priority sufficiently. The result of this test is considered to be suitable for presenting directions for future research, and it can be utilized as basic data for summarizing the performance standard of industrialization house of modular building in detail. KCI Citation Count: 0
Bibliography:http://dx.doi.org/10.12813/kieae.2018.18.1.031
ISSN:2288-968X
2288-9698
DOI:10.12813/kieae.2018.18.1.031