독립형 액화가스 저장탱크의 BOG 발생에 대한 실험적 분석
With the tightening of environmental regulations (i.e., IMO Tier III), natural gas (NG) has been spotlighted as an eco-friendly fuel with few air pollutants other than nitrogen oxides (NOx) and sulfur oxides (SOx). For reasons of economic efficiency, it is mainly stored and transported in a liquid s...
Saved in:
| Published in | Han-guk haeyang gonghak hoeji (Online) Vol. 32; no. 5; pp. 380 - 385 |
|---|---|
| Main Authors | , , , , , |
| Format | Journal Article |
| Language | Korean |
| Published |
한국해양공학회
2018
|
| Subjects | |
| Online Access | Get full text |
| ISSN | 1225-0767 2287-6715 |
| DOI | 10.26748/KSOE.2018.6.32.5.380 |
Cover
| Summary: | With the tightening of environmental regulations (i.e., IMO Tier III), natural gas (NG) has been spotlighted as an eco-friendly fuel with few air pollutants other than nitrogen oxides (NOx) and sulfur oxides (SOx). For reasons of economic efficiency, it is mainly stored and transported in a liquid state at $-163^{\circ}C$, which is a cryogenic temperature, using a liquefied gas storage tank. Accordingly, it is necessary to reduce the boil-off gas (BOG) occurrence due to the heat flow according to the temperature difference between the inside and outside of the storage tank. Therefore, in this study, a BOG measurement test on an independent-type storage tank made up of SUS304L was carried out. The test results showed the tendency for BOG occurrence according to the temperature under different filling ratios. |
|---|---|
| Bibliography: | KISTI1.1003/JNL.JAKO201833469090250 https://doi.org/10.26748/KSOE.2018.6.32.5.380 |
| ISSN: | 1225-0767 2287-6715 |
| DOI: | 10.26748/KSOE.2018.6.32.5.380 |