대구경 타원관을 적용한 건조기용 핀-관 열교환기의 성능특성

The objective of this paper is to provide design data of fin-tube heat exchanger which have a large diameter oval tube for dryer application. In this study, the heat transfer and pressure drop performance characteristics of the fin-tube heat exchanger were compared with Dittus-Boelter and a new corr...

Full description

Saved in:
Bibliographic Details
Published in설비공학 논문집, 27(1) Vol. 27; no. 1; pp. 8 - 13
Main Authors 배경진(Kyung-Jin Bae), 차동안(Dong-An Cha), 권오경(Oh-Kyung Kwon)
Format Journal Article
LanguageKorean
Published 대한설비공학회 2015
Subjects
Online AccessGet full text
ISSN1229-6422
2465-7611
DOI10.6110/KJACR.2015.27.1.008

Cover

More Information
Summary:The objective of this paper is to provide design data of fin-tube heat exchanger which have a large diameter oval tube for dryer application. In this study, the heat transfer and pressure drop performance characteristics of the fin-tube heat exchanger were compared with Dittus-Boelter and a new correlation equation using Wilson plot method. The simulation results based on section by section method were compared with experimental results. These results showed that a new correlation equation using Wilson plot method provided better prediction, about 3 to 12%, than the Dittus-Boelter equation, from the experiment comparison. Also, the pressure drop of simulation results showed much more deviation with the experimental results.
Bibliography:KISTI1.1003/JNL.JAKO201505458145361
http://www.sarek.or.kr
G704-000168.2015.27.1.001
ISSN:1229-6422
2465-7611
DOI:10.6110/KJACR.2015.27.1.008