전기용량성 섬유 압력센서를 이용한 호흡측정 시스템

In this paper, we proposed a wearable respiration measurement system with textile capacitive pressure sensor. Belt typed textile capacitive pressure sensor approach of respiration measurement, from which respiration signatures and rates can be derived in real-time for long-term monitoring, are prese...

Full description

Saved in:
Bibliographic Details
Published in전기학회 논문지 P권, 59(1) Vol. 59; no. 1; pp. 58 - 63
Main Authors 민세동(Se-Dong Min), 윤용현(Young-Hyun Yun), 이충근(Chung-Keun Lee), 신항식(Hang-Sik Shin), 조하경(Ha-Kyung Cho), 황선철(Seon-Cheol Hwang), 이명호(Myoung-Ho Lee)
Format Journal Article
LanguageKorean
Published 대한전기학회 2010
Subjects
Online AccessGet full text
ISSN1229-800X
2586-7792

Cover

More Information
Summary:In this paper, we proposed a wearable respiration measurement system with textile capacitive pressure sensor. Belt typed textile capacitive pressure sensor approach of respiration measurement, from which respiration signatures and rates can be derived in real-time for long-term monitoring, are presented. Belt typed textile capacitive pressure sensor has been developed for this measurement system. the distance change of two plates by the pressure of motion has been used for the respiration measurement in chest area. Respiration rates measured with the textile capacitive pressure sensor was compared with standard techniques on 8 human subjects. Accurate measurement of respiration rate with developed sensor system is shown. The data from the method comparison study is used to confirm theoretical estimates of change in capacitance by the distance change. The current version of respiratory rate detection system using textile capacitive pressure sensor can successfully measure respiration rate. It showed upper limit agreement of $3.7997{\times}10^{-7}$ RPM, and lower limit of agreement of $-3.8428{\times}10^{-7}$ RPM in Bland-Altman plot. From all subject, high correlation were shown(p<0.0001). The proposed measurement method could be used to monitor unconscious persons, avoiding the need to apply electrodes to the directly skin or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using textile capacitive pressure sensor offers a promising possibility of convenient measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range and quality of the rate-finding, broadening the potential application areas of this technology.
Bibliography:KISTI1.1003/JNL.JAKO201012640781175
G704-001568.2010.59.1.007
ISSN:1229-800X
2586-7792