In this study, we have developed a novel step detection algorithm for gait evaluation of patients with hemiplegia based on trunk accelerometry device. For this, we have used a bandpass filter and a least square acceleration (LSA) filter which is characterized by emphasizing the peak or valley point...
Saved in:
Published in | Journal of biomedical engineering research Vol. 30; no. 3; pp. 213 - 220 |
---|---|
Main Authors | , , , , , , , , , , , , , , , |
Format | Journal Article |
Language | Korean |
Published |
대한의용생체공학회
01.06.2009
|
Subjects | |
Online Access | Get full text |
ISSN | 1229-0807 2288-9396 |
Cover
Summary: | In this study, we have developed a novel step detection algorithm for gait evaluation of patients with hemiplegia based on trunk accelerometry device. For this, we have used a bandpass filter and a least square acceleration (LSA) filter which is characterized by emphasizing the peak or valley point of the acceleration signals for each 3-axis accelerometer signals. To evaluate the algorithm, the detected steps by developed algorithm and real steps by the motion analysis system were compared. As a result, we could obtain the sensitivity of 96.44%, the specificity of 99.94% and the accuracy of 99.90% for the patients' data sets and the sensitivity of 100%, the specificity of 99.93% and the accuracy of 99.93% for the normal data sets. In conclusion, the developed algorithm is useful for the step detection for patients with hemiplegia as well as normal subjects. |
---|---|