다중회귀분석을 통한 하수처리장 환경변화에 따른 적정 운전조건 도출 방법 연구
In this study, the method which could provide the proper operation condition for abnormal conditions at sewage treatment plant was suggested. For this analysis, the operating data of one year of 2011 has been collected from a sewage treatment plant for the media process. The abnormal condition was s...
Saved in:
Published in | 한국수처리학회지, 22(1) pp. 39 - 46 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | Korean |
Published |
한국수처리학회
28.02.2014
|
Subjects | |
Online Access | Get full text |
ISSN | 1225-7192 2289-0076 |
Cover
Summary: | In this study, the method which could provide the proper operation condition for abnormal conditions at sewage treatment plant was suggested. For this analysis, the operating data of one year of 2011 has been collected from a sewage treatment plant for the media process. The abnormal condition was set up the winter season and the rainy periods. The multiple regression analysis was divided with 4 CASE according to the removal of outliers and the log transformation of variables. The criteria for operation conditions was set to 60% of water quality standards in CODMn, T-N considering the safety factor. As a result of this study, the proper operation condition for abnormal conditions at sewage treatment plant could be provided by multiple regression analysis. The sewage treatment plant that is collected operation data for this study was being operated within the proper operation range that is provided by multiple regression analysis. KCI Citation Count: 0 |
---|---|
Bibliography: | G704-001415.2014.22.1.007 |
ISSN: | 1225-7192 2289-0076 |