VR을 이용한 균형능력 측정장비의 성능평가

Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipme...

Full description

Saved in:
Bibliographic Details
Published inJournal of the Korean Society of Integrative Medicine Vol. 8; no. 3; pp. 33 - 41
Main Authors 윤상철, Yoon Sangcheol, 안호원, An Howon, 안택원, Ahn Taekwon, 최해성, Choi Haesung, 이병권, Lee Byoungkwon, 서동권, Seo Dongkwon, 이규환, Lee Kyuhwan, 정상우, Jung Sangwoo, 이재훈, Yi Jaehoon
Format Journal Article
LanguageKorean
Published 대한통합의학회 30.09.2020
Subjects
Online AccessGet full text
ISSN2288-1174

Cover

More Information
Summary:Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipment that measures the balance of the body using changes in body segment and pressure using the acceleration sensor to compensate for the disadvantages of the existing equipment. Methods : To this end, balance ability was measured in 43 healthy male/female adults without orthopedic injuries and nervous system damage in the last 6 months. in a situation where the visual information was restricted by Virtual Reality (VR) gear, all subjects measured and evaluated the balance ability utilizing the new equipment. Balance measurement (Prime Medilab, Korea) and Wii fit (Nintendo, Japan) were used to measure the balance ability of the subjects, and the balance ability test was performed in 4 postures using each device for data acquisition. The test duration for each posture was 30 seconds. For data acquisition, the average value of three experiments measured using each equipment was analyzed, and the statistical test was performed using the independent sample and the corresponding sample t-test, and the significance level was set to α=.05. Results : As a result of measuring the balance ability using individual equipment, blocking visual information using VR gear, the average speed, maximum speed, and moving area of the COP increased equally. It was found that the obtained absolute size of the result in Wii was somewhat larger than that of BM. Conclusion : It is considered that in the future research, it is necessary to measure changes in the body’s center of gravity through image analysis, etc., to make clear comparison and evaluation of the usability.
Bibliography:Korea Society of Intergration Medicine
KISTI1.1003/JNL.JAKO202027265523895
ISSN:2288-1174