Skin Safety Evaluation of HKP-210
HKP-210 is a anodyne poultics containing 3 mg Ketoprofen in 1.0g vehicle. We performed 48 hours closed patch test for evaluation of skin safety of HKP-210. Test materials were HKP-210, HKP-210 base, Papsalon G and 0.3% Ketoprofen/pet. Test subjects were 48 out patients with skin diseases who present...
Saved in:
| Published in | Skin research Vol. 27; no. 3; pp. 375 - 378 |
|---|---|
| Main Authors | , |
| Format | Journal Article |
| Language | English Japanese |
| Published |
Meeting of Osaka Dermatological Association
1985
日本皮膚科学会大阪地方会 |
| Subjects | |
| Online Access | Get full text |
| ISSN | 0018-1390 1884-541X |
| DOI | 10.11340/skinresearch1959.27.375 |
Cover
| Abstract | HKP-210 is a anodyne poultics containing 3 mg Ketoprofen in 1.0g vehicle. We performed 48 hours closed patch test for evaluation of skin safety of HKP-210. Test materials were HKP-210, HKP-210 base, Papsalon G and 0.3% Ketoprofen/pet. Test subjects were 48 out patients with skin diseases who presented our clinic during from March to August 1984. Patch test reactions were evaluated according to Japanese standard. The patch test positive rate of Papsalon (>±) was higher than those of HKP-210 and HKP-210 base significantly (p=0.073). The patch test positive rate of Ketoprofen 0.3%/pet was lower than that of Papsalon. So we decided HKP-210 might be used safely being applied correctly. |
|---|---|
| AbstractList | HKP-210 is a anodyne poultics containing 3 mg Ketoprofen in 1.0g vehicle. We performed 48 hours closed patch test for evaluation of skin safety of HKP-210. Test materials were HKP-210, HKP-210 base, Papsalon G and 0.3% Ketoprofen/pet. Test subjects were 48 out patients with skin diseases who presented our clinic during from March to August 1984. Patch test reactions were evaluated according to Japanese standard. The patch test positive rate of Papsalon (>±) was higher than those of HKP-210 and HKP-210 base significantly (p=0.073). The patch test positive rate of Ketoprofen 0.3%/pet was lower than that of Papsalon. So we decided HKP-210 might be used safely being applied correctly. HKP-210 is a anodyne poultics containing 3 mg Ketoprofen in 1.0g vehicle. We performed 48 hours closed patch test for evaluation of skin safety of HKP-210. Test materials were HKP-210, HKP-210 base, Papsalon G and 0.3% Ketoprofen/pet. Test subjects were 48 out patients with skin diseases who presented our clinic during from March to August 1984. Patch test reactions were evaluated according to Japanese standard. The patch test positive rate of Papsalon (>±) was higher than those of HKP-210 and HKP-210 base significantly (p=0.073). The patch test positive rate of Ketoprofen 0.3%/pet was lower than that of Papsalon. So we decided HKP-210 might be used safely being applied correctly. HKP-210は久光製薬株式会社より開発された消炎鎮痛剤作用を有するケトプロフェンを膏体1g中に3mg含有する経皮吸収型貼付剤で, 整形外科領域の炎症性疼痛性疾患治療薬である。今回我々はHKP-210の皮膚安全性についての検討を依頼されたので名大分院皮膚科を受診した皮膚疾患患者48名を対象に48時間closed patch testを施行した。結果をMann Whitoney U testにより検定した結果48時間の判定時の±以上の陽性率はパップサロンG>HKP-210及び同基剤 (p=0.073) であった。また0.3%ケトプロフェン含有白色ワセリンは既販のパップサロンGに比較して皮膚刺激反応例が有意に少なかった。以上の結果よりHKP-210は整形外科領域に於ける局所治療剤として安全に応用出来る製剤と判定した。 |
| Author | MATSUNAGA, Kayoko HAYAKAWA, Ritsuko |
| Author_FL | 早川 律子 松永 佳世子 |
| Author_FL_xml | – sequence: 1 fullname: 早川 律子 – sequence: 2 fullname: 松永 佳世子 |
| Author_xml | – sequence: 1 fullname: MATSUNAGA, Kayoko organization: Division of Dermatology, Nagoya University Branch Hospital – sequence: 1 fullname: HAYAKAWA, Ritsuko organization: Division of Dermatology, Nagoya University Branch Hospital |
| BackLink | https://cir.nii.ac.jp/crid/1390282679777947520$$DView record in CiNii |
| BookMark | eNpdkEFLw0AQhRepYKz9DxG8Ju7sZrPZo5RqxYJCFbwtk3ViN8ZEslHov29KxINzeHP53uPxztms7VpiLAaeAsiMX4cP3_YUCHu3A6NMKnQqtTphERRFlqgMXmcs4hyKBKThZ2wRQs3Hy0GYXEfscjsmxFusaNjHqx9svnHwXRt3Vbx-eEoE8At2WmETaPH75-zldvW8XCebx7v75c0mqYVQQzL2cbxESaSqSjsBopQFubzEPAfAkkOZa0PGcXjLnERFDpwrtCkNcVJGztnVlNt6b50_6rGyKMTo01qbTCvBR2wzYXUY8J3sV-8_sd9b7AfvGrL_F7FCWznJOMwf5nbYW2rlAbCgXzU |
| ContentType | Journal Article |
| Copyright | Meeting of Osaka Dermatological Association |
| Copyright_xml | – notice: Meeting of Osaka Dermatological Association |
| DBID | RYH |
| DOI | 10.11340/skinresearch1959.27.375 |
| DatabaseName | CiNii Complete |
| DatabaseTitleList | |
| DeliveryMethod | fulltext_linktorsrc |
| DocumentTitleAlternate | HKP‐210の皮膚安全性 |
| DocumentTitle_FL | HKP‐210の皮膚安全性 |
| EISSN | 1884-541X |
| EndPage | 378 |
| ExternalDocumentID | 130004044864 article_skinresearch1959_27_3_27_3_375_article_char_en |
| GroupedDBID | ALMA_UNASSIGNED_HOLDINGS F5P JSF KQ8 RJT RYH |
| ID | FETCH-LOGICAL-j225t-113c0ba3ee5ff7c212b38ec6ba6611ab01b679e9c01d4c3a5ec1cc879b9e0e593 |
| ISSN | 0018-1390 |
| IngestDate | Thu Jun 26 23:43:51 EDT 2025 Wed Sep 03 06:29:27 EDT 2025 |
| IsDoiOpenAccess | true |
| IsOpenAccess | true |
| IsPeerReviewed | false |
| IsScholarly | true |
| Issue | 3 |
| Language | English Japanese |
| LinkModel | OpenURL |
| MergedId | FETCHMERGED-LOGICAL-j225t-113c0ba3ee5ff7c212b38ec6ba6611ab01b679e9c01d4c3a5ec1cc879b9e0e593 |
| OpenAccessLink | https://www.jstage.jst.go.jp/article/skinresearch1959/27/3/27_3_375/_article/-char/en |
| PageCount | 4 |
| ParticipantIDs | nii_cinii_1390282679777947520 jstage_primary_article_skinresearch1959_27_3_27_3_375_article_char_en |
| PublicationCentury | 1900 |
| PublicationDate | 1985 |
| PublicationDateYYYYMMDD | 1985-01-01 |
| PublicationDate_xml | – year: 1985 text: 1985 |
| PublicationDecade | 1980 |
| PublicationTitle | Skin research |
| PublicationTitleAlternate | Skin Research |
| PublicationTitle_FL | 皮膚 Skin Research |
| PublicationYear | 1985 |
| Publisher | Meeting of Osaka Dermatological Association 日本皮膚科学会大阪地方会 |
| Publisher_xml | – name: Meeting of Osaka Dermatological Association – name: 日本皮膚科学会大阪地方会 |
| References | 1. 中部パッチテスト研究班: Finn-chamber, KIchamber, AL-testの評価, 皮膚, 21: 196-204, 1979. 3. 早川律子, 松永佳世子, 大岩久美子, 請井智香子: KPG-200の皮膚安全性に関する検討, 皮膚, 25: 199-206, 1983. 2. 川村太郎, 笹川正二, 増田勉, 本田史朗, 木下正子, 原田昭太郎, 石崎進, 永井隆吉, 広川浩一, 安西喬, 姉小路公久, 肥田野信, 川野正, 池上一郎, 佐藤重男, 青山卓夫: 貼布試験標準化の基礎的研究, 日皮会誌, 80: 301-314, 1970. |
| References_xml | – reference: 1. 中部パッチテスト研究班: Finn-chamber, KIchamber, AL-testの評価, 皮膚, 21: 196-204, 1979. – reference: 2. 川村太郎, 笹川正二, 増田勉, 本田史朗, 木下正子, 原田昭太郎, 石崎進, 永井隆吉, 広川浩一, 安西喬, 姉小路公久, 肥田野信, 川野正, 池上一郎, 佐藤重男, 青山卓夫: 貼布試験標準化の基礎的研究, 日皮会誌, 80: 301-314, 1970. – reference: 3. 早川律子, 松永佳世子, 大岩久美子, 請井智香子: KPG-200の皮膚安全性に関する検討, 皮膚, 25: 199-206, 1983. |
| SSID | ssj0000612967 ssib002004101 ssib058492864 ssib058492872 ssib029852167 ssib005879643 |
| Score | 1.247396 |
| Snippet | HKP-210 is a anodyne poultics containing 3 mg Ketoprofen in 1.0g vehicle. We performed 48 hours closed patch test for evaluation of skin safety of HKP-210.... |
| SourceID | nii jstage |
| SourceType | Publisher |
| StartPage | 375 |
| SubjectTerms | ケトプロフェン パッチテスト パップ剤 貼付剤 非ステロイド |
| Title | Skin Safety Evaluation of HKP-210 |
| URI | https://www.jstage.jst.go.jp/article/skinresearch1959/27/3/27_3_375/_article/-char/en https://cir.nii.ac.jp/crid/1390282679777947520 |
| Volume | 27 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| ispartofPNX | Skin research, 1985, Vol.27(3), pp.375-378 |
| journalDatabaseRights | – providerCode: PRVAFT databaseName: Open Access Digital Library customDbUrl: eissn: 1884-541X dateEnd: 20011231 omitProxy: true ssIdentifier: ssj0000612967 issn: 0018-1390 databaseCode: KQ8 dateStart: 19590101 isFulltext: true titleUrlDefault: http://grweb.coalliance.org/oadl/oadl.html providerName: Colorado Alliance of Research Libraries |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lj9MwELbY5cIFLQLEAouCxK1KSfyI42OEFioqllcrllNkO47UrtQimj0sv57PtZuGBcTjYrVOFNkzk_FnZ-YbQp7ZvM0AVG1Ki1KlwP9lqg1ed97mSrS6YUL53OE3Z8Vkzl-fi_Ndoe2YXdKZsf32y7yS_9Eq-qBXnyX7D5rtH4oO_IZ-0ULDaP9Kx75y1mijWx92uaft3p7NT9-lNEZyLgc3R26f_gx4Un2uptWnavRh0W0uL9a9_KvZx_lZ9aoaTfXVOvY3IVsuFL8JoUHO7cKm3270hYb78hC4d6jXlR_dY44tJQv1O8cueMSy5Kng27o2vcsM6fzRNNjA_7FQBiUupSxU5_nZSzPu4xo3mPdu2p7jZkzluH_ADxzY_psbvA1MqeAH5Cb1Zy_-A_z7wVbJM4dlA6qxUg6pxiiEQ_M91ALuUnTATB_-xxzisIoDCRWBcjVKZRcIhtE__83YgWOWQPWeruFgtVgMoMrsiNyOe4ykCgZzh9xY6rvkqdd_Eowl2RtLsm6TaCz3yPzl6ezFJI31MdIlvHCXYiQ2M5o5J9pWWoAQw0pnC6MBunJtstwUUjlls7zhlmnhbG4t5GKUy5xQ7D45XK1X7gFJPNJuWs3RNLxVZVkY45iUeJJTvBHH5DTMq_4SSFDqaPT1dUHUVNYsNJBHf5vPIcQre0xOIJbaLnzrZYodP8YoJZYFKWj28A_XH5Fb3szDGdhjcth9vXQnQIWdebI1h-8sRFTz |
| linkProvider | Colorado Alliance of Research Libraries |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Skin+safety+evaluation+of+HKP-210&rft.jtitle=Skin+research&rft.au=HAYAKAWA+Ritsuko&rft.au=MATSUNAGA+Kayoko&rft.date=1985&rft.pub=Meeting+of+Osaka+Dermatological+Association&rft.issn=0018-1390&rft.eissn=1884-541X&rft.volume=27&rft.issue=3&rft.spage=375&rft.epage=378&rft_id=info:doi/10.11340%2Fskinresearch1959.27.375&rft.externalDocID=130004044864 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0018-1390&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0018-1390&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0018-1390&client=summon |