Proposal for a New Radiated-Emission Test Method Using a Completely Absorber - Lined Chamber Without Groundplane

Completely absorber-lined chambers can be used for standard radiated-emission tests, if a specific test procedure as outlined in this paper is followed. Field-strengths measured in such a chamber can be corrected to obtain open-site equivalents by applying conversion factors, which are functions of...

Full description

Saved in:
Bibliographic Details
Published in9th International Zurich Symposium and Technical Exhibition on Electromagnetic Compatibility pp. 299 - 304
Main Author Garn, Heinrich F.
Format Conference Proceeding
LanguageEnglish
Published IEEE 12.03.1991
Subjects
Online AccessGet full text
ISBN9781509031948
1509031944
DOI10.23919/EMC.1991.10781064

Cover

More Information
Summary:Completely absorber-lined chambers can be used for standard radiated-emission tests, if a specific test procedure as outlined in this paper is followed. Field-strengths measured in such a chamber can be corrected to obtain open-site equivalents by applying conversion factors, which are functions of frequency and polarization. Excellent equivalence to a standard test will be achieved for small, e.g. hand-held equipment and for desk-top equipment. For large cabinets there is an unavoidable uncertainty in the conversion of up to ±11 dB.
ISBN:9781509031948
1509031944
DOI:10.23919/EMC.1991.10781064