Phase unwrapping in 4D MR flow with a 4D single-step laplacian algorithm

Purpose To introduce and demonstrate a method for unwrapping 4D flow data by utilizing continuity constraints in all four available dimensions. Materials and Methods A Laplacian‐based algorithm for unwrapping phase data was expanded to unwrap along the temporal dimension in addition to all three spa...

Full description

Saved in:
Bibliographic Details
Published inJournal of magnetic resonance imaging Vol. 43; no. 4; pp. 833 - 842
Main Authors Loecher, Michael, Schrauben, Eric, Johnson, Kevin M., Wieben, Oliver
Format Journal Article
LanguageEnglish
Published United States Blackwell Publishing Ltd 01.04.2016
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text
ISSN1053-1807
1522-2586
1522-2586
DOI10.1002/jmri.25045

Cover

More Information
Summary:Purpose To introduce and demonstrate a method for unwrapping 4D flow data by utilizing continuity constraints in all four available dimensions. Materials and Methods A Laplacian‐based algorithm for unwrapping phase data was expanded to unwrap along the temporal dimension in addition to all three spatial dimensions. The method was tested on simulated blood flow under varying vessel diameters and velocity encoding (Venc) values. The algorithm was also tested in the aorta of five volunteers, with wrapped data acquired with Venc = 80 cm/s and 40 cm/s. Unwrapping performance was measured visually and in comparison to a high Venc reference free of phase wrapping. Ten patients with aortic coarctations with clinical Venc values and lower‐Venc reconstructions were corrected and scored by blinded reviewers on a 0–3 scale. Results Simulated data were completely unwrapped for most clinically relevant levels of velocity aliasing using the proposed method. In vivo data in the aorta were completely unwrapped for cases of moderate wrapping (Venc = 80 cm/s, peak velocities = ∼160 cm/s), while residual aliasing remained for the more considerably aliased datasets (Venc = 40 cm/s). Improvements were seen in scoring (mean score improved by 1.1 and 2.2 for clinical and low‐Venc datasets, respectively) by the blinded reviewers in the patient cohort for both standard and low‐Venc reconstructions. Conclusion A computationally fast, fully automated, easy to use, and parameter‐free single‐step method for unwrapping 4D flow data is shown to be effective for use in most common clinical occurrences of velocity aliasing. J. Magn. Reson. Imaging 2016;43:833–842
Bibliography:istex:CBC7471D41C30BC97BEE5EF290796F37FC991221
ArticleID:JMRI25045
ark:/67375/WNG-F31GSXQK-X
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1053-1807
1522-2586
1522-2586
DOI:10.1002/jmri.25045