Phase unwrapping in 4D MR flow with a 4D single-step laplacian algorithm
Purpose To introduce and demonstrate a method for unwrapping 4D flow data by utilizing continuity constraints in all four available dimensions. Materials and Methods A Laplacian‐based algorithm for unwrapping phase data was expanded to unwrap along the temporal dimension in addition to all three spa...
Saved in:
| Published in | Journal of magnetic resonance imaging Vol. 43; no. 4; pp. 833 - 842 |
|---|---|
| Main Authors | , , , |
| Format | Journal Article |
| Language | English |
| Published |
United States
Blackwell Publishing Ltd
01.04.2016
Wiley Subscription Services, Inc |
| Subjects | |
| Online Access | Get full text |
| ISSN | 1053-1807 1522-2586 1522-2586 |
| DOI | 10.1002/jmri.25045 |
Cover
| Summary: | Purpose
To introduce and demonstrate a method for unwrapping 4D flow data by utilizing continuity constraints in all four available dimensions.
Materials and Methods
A Laplacian‐based algorithm for unwrapping phase data was expanded to unwrap along the temporal dimension in addition to all three spatial dimensions. The method was tested on simulated blood flow under varying vessel diameters and velocity encoding (Venc) values. The algorithm was also tested in the aorta of five volunteers, with wrapped data acquired with Venc = 80 cm/s and 40 cm/s. Unwrapping performance was measured visually and in comparison to a high Venc reference free of phase wrapping. Ten patients with aortic coarctations with clinical Venc values and lower‐Venc reconstructions were corrected and scored by blinded reviewers on a 0–3 scale.
Results
Simulated data were completely unwrapped for most clinically relevant levels of velocity aliasing using the proposed method. In vivo data in the aorta were completely unwrapped for cases of moderate wrapping (Venc = 80 cm/s, peak velocities = ∼160 cm/s), while residual aliasing remained for the more considerably aliased datasets (Venc = 40 cm/s). Improvements were seen in scoring (mean score improved by 1.1 and 2.2 for clinical and low‐Venc datasets, respectively) by the blinded reviewers in the patient cohort for both standard and low‐Venc reconstructions.
Conclusion
A computationally fast, fully automated, easy to use, and parameter‐free single‐step method for unwrapping 4D flow data is shown to be effective for use in most common clinical occurrences of velocity aliasing. J. Magn. Reson. Imaging 2016;43:833–842 |
|---|---|
| Bibliography: | istex:CBC7471D41C30BC97BEE5EF290796F37FC991221 ArticleID:JMRI25045 ark:/67375/WNG-F31GSXQK-X ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
| ISSN: | 1053-1807 1522-2586 1522-2586 |
| DOI: | 10.1002/jmri.25045 |