Power detection of fluctuated load based on inverse-time-lag algorithm and the application in energy-saving controller of beaming-pumping unit
This paper proposes an inverse-time-lag algorithm combined with one-step inertia filtering algorithm on the analysis of load fluctuation of beaming-pumping and the reason why it occurs in oilfield, taking an example of power detection of beaming-pumping unit related to oilfield load fluctuation. A c...
Saved in:
| Published in | ICEMS'2001 : proceedings of the fifth International Conference on Electrical Machines and Systems, August 18-20, 2001, Shenyang, China Vol. 2; pp. 1223 - 1225 vol.2 |
|---|---|
| Main Authors | , , , |
| Format | Conference Proceeding |
| Language | English |
| Published |
IEEE
2001
|
| Subjects | |
| Online Access | Get full text |
| ISBN | 7506251159 9787506251150 |
| DOI | 10.1109/ICEMS.2001.971902 |
Cover
| Summary: | This paper proposes an inverse-time-lag algorithm combined with one-step inertia filtering algorithm on the analysis of load fluctuation of beaming-pumping and the reason why it occurs in oilfield, taking an example of power detection of beaming-pumping unit related to oilfield load fluctuation. A close loop controller based on this theory enabled the generator to change its working condition and thus the output can be increased or decreased automatically. The effect of energy saving is remarkable. |
|---|---|
| ISBN: | 7506251159 9787506251150 |
| DOI: | 10.1109/ICEMS.2001.971902 |