A Real-Time Atrial Fibrillation Detection Algorithm Based on the Instantaneous State of Heart Rate

Atrial fibrillation (AF), the most frequent cause of cardioembolic stroke, is increasing in prevalence as the population ages, and presents with a broad spectrum of symptoms and severity. The early identification of AF is an essential part for preventing the possibility of blood clotting and stroke....

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 10; no. 9; p. e0136544
Main Authors Zhou, Xiaolin, Ding, Hongxia, Wu, Wanqing, Zhang, Yuanting
Format Journal Article
LanguageEnglish
Published United States Public Library of Science 16.09.2015
Public Library of Science (PLoS)
Subjects
Online AccessGet full text
ISSN1932-6203
1932-6203
DOI10.1371/journal.pone.0136544

Cover

More Information
Summary:Atrial fibrillation (AF), the most frequent cause of cardioembolic stroke, is increasing in prevalence as the population ages, and presents with a broad spectrum of symptoms and severity. The early identification of AF is an essential part for preventing the possibility of blood clotting and stroke. In this work, a real-time algorithm is proposed for accurately screening AF episodes in electrocardiograms. This method adopts heart rate sequence, and it involves the application of symbolic dynamics and Shannon entropy. Using novel recursive algorithms, a low-computational complexity can be obtained. Four publicly-accessible sets of clinical data (Long-Term AF, MIT-BIH AF, MIT-BIH Arrhythmia, and MIT-BIH Normal Sinus Rhythm Databases) were used for assessment. The first database was selected as a training set; the receiver operating characteristic (ROC) curve was performed, and the best performance was achieved at the threshold of 0.639: the sensitivity (Se), specificity (Sp), positive predictive value (PPV) and overall accuracy (ACC) were 96.14%, 95.73%, 97.03% and 95.97%, respectively. The other three databases were used for independent testing. Using the obtained decision-making threshold (i.e., 0.639), for the second set, the obtained parameters were 97.37%, 98.44%, 97.89% and 97.99%, respectively; for the third database, these parameters were 97.83%, 87.41%, 47.67% and 88.51%, respectively; the Sp was 99.68% for the fourth set. The latest methods were also employed for comparison. Collectively, results presented in this study indicate that the combination of symbolic dynamics and Shannon entropy yields a potent AF detector, and suggest this method could be of practical use in both clinical and out-of-clinical settings.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
Conceived and designed the experiments: XLZ. Performed the experiments: XLZ HXD. Analyzed the data: XLZ HXD. Contributed reagents/materials/analysis tools: HXD. Wrote the paper: XLZ HXD WQW. Provided suggestions and comments as well as much work in revising the manuscript: WQW YTZ.
Competing Interests: The authors have declared that no competing interests exist.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0136544