Quadriceps handheld dynamometry during the post-ICU trajectory: using strictly the same body position is mandatory for repeated measures

Background The level of quadriceps strength (QS) generated in the supine or seated position is not similar. For QS follow-up from intensive care unit (ICU) stay to recovery, getting comparable measures is essential. This study aimed to develop and validate new equations for estimating QS in a given...

Full description

Saved in:
Bibliographic Details
Published inIntensive Care Medicine Experimental Vol. 11; no. 1; pp. 39 - 12
Main Authors Rousseau, Anne-Françoise, Dardenne, Nadia, Kellens, Isabelle, Bornheim, Stephen, Misset, Benoit, Croisier, Jean-Louis
Format Journal Article Web Resource
LanguageEnglish
Published Cham Springer Science and Business Media LLC 03.07.2023
Springer International Publishing
Springer Nature B.V
SpringerOpen
Subjects
Online AccessGet full text
ISSN2197-425X
2197-425X
DOI10.1186/s40635-023-00523-5

Cover

More Information
Summary:Background The level of quadriceps strength (QS) generated in the supine or seated position is not similar. For QS follow-up from intensive care unit (ICU) stay to recovery, getting comparable measures is essential. This study aimed to develop and validate new equations for estimating QS in a given position based on the measurement taken in another one. Methods and results Isometric QS was measured using a handheld dynamometer and a standardized protocol in a supine and in a seated position. In a first cohort of 77 healthy adults, two QS conversion equations were developed using a multivariate model integrating independent parameters such as age, sex, body mass index (BMI) and baseline QS. These equations were tested in two cohorts for external validation, using the interclass correlation coefficient (ICC) and Bland–Altman graphical method. Only one was validated in the second cohort (62 different healthy adults): the ICC was 0.87 (95% CI 0.59–0.94) and the bias was − 0.49 N/Kg (limits of agreement: − 1.76–0.78 N/kg). However, this equation did not perform well in the third cohort (50 ICU survivors): the ICC was 0.60 (95% CI 0.24–0.78), and the bias was − 0.53 N/Kg (limits of agreement: − 1.01–2.07 N/kg). Conclusions As no conversion equation has been validated in the present study, repeated QS measurements should be performed strictly in the same standardized and documented position.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
scopus-id:2-s2.0-85163829678
ISSN:2197-425X
2197-425X
DOI:10.1186/s40635-023-00523-5