Accuracy of computer-assisted vertical cup-to-disk ratio grading for glaucoma screening

Glaucoma screening can be performed by assessing the vertical-cup-to-disk ratio (VCDR) of the optic nerve head from fundus photography, but VCDR grading is inherently subjective. This study investigated whether computer software could improve the accuracy and repeatability of VCDR assessment. In thi...

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 14; no. 8; p. e0220362
Main Authors Snyder, Blake M., Nam, Sang Min, Khunsongkiet, Preeyanuch, Ausayakhun, Sakarin, Leeungurasatien, Thidarat, Leiter, Maxwell R., Sevastopolsky, Artem, Joye, Ashlin S., Berlinberg, Elyse J., Liu, Yingna, Ramirez, David A., Moe, Caitlin A., Ausayakhun, Somsanguan, Stamper, Robert L., Keenan, Jeremy D.
Format Journal Article
LanguageEnglish
Published United States Public Library of Science 08.08.2019
Public Library of Science (PLoS)
Subjects
Online AccessGet full text
ISSN1932-6203
1932-6203
DOI10.1371/journal.pone.0220362

Cover

More Information
Summary:Glaucoma screening can be performed by assessing the vertical-cup-to-disk ratio (VCDR) of the optic nerve head from fundus photography, but VCDR grading is inherently subjective. This study investigated whether computer software could improve the accuracy and repeatability of VCDR assessment. In this cross-sectional diagnostic accuracy study, 5 ophthalmologists independently assessed the VCDR from a set of 200 optic disk images, with the median grade used as the reference standard for subsequent analyses. Eight non-ophthalmologists graded each image by two different methods: by visual inspection and with assistance from a custom-made publicly available software program. Agreement with the reference standard grade was assessed for each method by calculating the intraclass correlation coefficient (ICC), and the sensitivity and specificity determined relative to a median ophthalmologist grade of ≥0.7. VCDR grades ranged from 0.1 to 0.9 for visual assessment and from 0.1 to 1.0 for software-assisted grading, with a median grade of 0.4 for each. Agreement between each of the 8 graders and the reference standard was higher for visual inspection (median ICC 0.65, interquartile range 0.57 to 0.82) than for software-assisted grading (median ICC 0.59, IQR 0.44 to 0.71); P = 0.02, Wilcoxon signed-rank test). Visual inspection and software assistance had similar sensitivity and specificity for detecting glaucomatous cupping. The computer software used in this study did not improve the reproducibility or validity of VCDR grading from fundus photographs compared with simple visual inspection. More clinical experience was correlated with higher agreement with the ophthalmologist VCDR reference standard.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
Competing Interests: AS previously worked for Youth Laboratories, LLC, which is developing automated algorithms potential glaucoma detection. This does not alter the authors' adherence to PLOS ONE policies on sharing data and materials.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0220362