A novel paclitaxel coated balloon with increased drug transfer for treatment of complex vascular lesions

Drug coated balloons (DCB) with paclitaxel (Ptx) dose of 2-3.5 μg/mm2 balloon surface inhibit restenosis with different effectiveness and duration of success. A clinical dose finding study is not known for any of the currently marketed products. The aim of the present preclinical trial was to invest...

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 16; no. 10; p. e0259106
Main Authors Gemeinhardt, Ole, Schnorr, Beatrix, Speck, Ulrich, Scheller, Bruno
Format Journal Article
LanguageEnglish
Published United States Public Library of Science 29.10.2021
Public Library of Science (PLoS)
Subjects
Online AccessGet full text
ISSN1932-6203
1932-6203
DOI10.1371/journal.pone.0259106

Cover

More Information
Summary:Drug coated balloons (DCB) with paclitaxel (Ptx) dose of 2-3.5 μg/mm2 balloon surface inhibit restenosis with different effectiveness and duration of success. A clinical dose finding study is not known for any of the currently marketed products. The aim of the present preclinical trial was to investigate a novel DCB coated with 6 μg Ptx/mm2 in a porcine model. The current study investigated a DCB with a novel, modified iopromide based matrix with 6 μg Ptx/mm2. Drug transfer to the vessel wall of peripheral arteries was compared with a dose of 3 μg Ptx/mm2 and two fully overlapping DCB with 3 μg Ptx/mm2, each. Ptx concentration in the vessel wall after drug transfer was about twice as high for balloons with 6 μg/mm2 (1957±1472 μg/g) and two overlapping DCB with 3 μg Ptx/mm2, each (1287±619 μg/g) compared to a single balloon with 3 μg Ptx/mm2, (787±738 μg/g), with statistical significant differences for 1x6 μg/mm2 vs. 1x3 μg/mm2 (p = 0.017) but not for 2x3 μg/mm2 vs. 1x3 μg/mm2 (p = 0.184) and 1x6 μg/mm2 vs. 2x3 μg/mm2 (p = 0.178). The proportion of residual Ptx on balloon after treatment was similar for all groups between 6±1% and 10±3% of dose on balloon. The dose of 6 μg Ptx/mm2 was successfully as well as reproducibly coated on conventional balloon catheters. Increased Ptx on balloons resulted in increased drug concentration in the vessel wall. A single balloon with 6 μg Ptx/mm2 seems to provide double dose compared to 3 μg Ptx/mm2, facilitates the procedure, and may reduce medico-economic cost compared to the use of two standard DCB.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
Competing Interests: OG is coinventor of a patent application, applicants Charité – Universitätsmedizin Berlin and InnoRo GmbH, Berlin, Germany. US and BS are shareholders of InnoRa GmbH. This does not alter our adherence to PLOS ONE policies on sharing data and materials.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0259106