Image review on mobile devices for suspected stroke patients: Evaluation of the mRay software solution

Software solutions such as mRay allow review of radiological images on handheld devices. We investigated if the quality is adequate for evaluating CT scans of patients with suspected stroke. 50 patients (Median age 80 years, 28 females) were retrospectively selected. All patients had undergone multi...

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 14; no. 6; p. e0219051
Main Authors Brehm, Alex, Maus, Volker, Khadhraoui, Eya, Psychogios, Marios-Nikos
Format Journal Article
LanguageEnglish
Published United States Public Library of Science 28.06.2019
Public Library of Science (PLoS)
Subjects
Online AccessGet full text
ISSN1932-6203
1932-6203
DOI10.1371/journal.pone.0219051

Cover

More Information
Summary:Software solutions such as mRay allow review of radiological images on handheld devices. We investigated if the quality is adequate for evaluating CT scans of patients with suspected stroke. 50 patients (Median age 80 years, 28 females) were retrospectively selected. All patients had undergone multidetector CT angiography ± perfusion and presented with clinical signs of acute stroke. Out of the 50 patients, 19 had large-vessel occlusion (LVO), 5 had intracranial hemorrhage (ICH), 10 had severe intracranial stenosis of at least one major vessel, 2 had intracranial tumor and 15 had no or an unrelated pathology. One experienced neuroradiologist and one resident scored the anonymized pictures separately on two handheld devices (iPhone 7 Plus, MED-TAB) equipped with mRay Software and on a PACS workstation. Each case was reviewed on all three devices with a break in-between of at least 12 weeks. The scoring on the traditional workstation was compared with the two handheld devices, regarding detection of early ischemic signs, LVOs, CBV/CBF-mismatch, ICHs and severe stenosis. Both raters were asked to rate the diagnostic quality of both handheld devices regarding detection of LVOs, ICHs, early ischemic signs and overall. All LVOs, intracranial tumors and ICHs were detected on both mobile devices. There was no significant difference in the rating of CCT and CBF ASPECTS between all three devices, while the sensitivity for detecting a CBF/CBV-mismatch was above 80% on both devices. Both raters assessed the diagnostic quality to be sufficient on both mobile devices to base treatment decisions on. Software solutions such as mRay for handheld devices provide adequate diagnostic quality for the review of CT scans of suspected stroke patients.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
Competing Interests: The authors have declared that no competing interests exist.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0219051