The curative effect analysis of peripherally inserted central venous catheter catheterization for tumor patients under the guidance of new medical guide wire
Objective To report a method of PICC catheterization with the aid of a new medical guide wire, and to discuss the curative effect. Methods Five hundred and thirteen patients who visited our hospital from January 2013 to December 2019 for PICC catheterization were selected as study subjects. Random n...
Saved in:
Published in | European journal of medical research Vol. 26; no. 1; pp. 99 - 6 |
---|---|
Main Author | |
Format | Journal Article |
Language | English |
Published |
London
BioMed Central
28.08.2021
BioMed Central Ltd BMC |
Subjects | |
Online Access | Get full text |
ISSN | 2047-783X 0949-2321 2047-783X |
DOI | 10.1186/s40001-021-00571-1 |
Cover
Summary: | Objective
To report a method of PICC catheterization with the aid of a new medical guide wire, and to discuss the curative effect.
Methods
Five hundred and thirteen patients who visited our hospital from January 2013 to December 2019 for PICC catheterization were selected as study subjects. Random number method was used to group patients. General information was recorded for both groups. Patients in the observation group received catheterization with the aid of a new medical guide wire. The control group received catheterization via conventional guide wire. The success rate of the first catheterization, the success rate of the catheterization, the timing of the catheterization, the complications and the position of the catheter end were compared between the two groups.
Results
There was no significant difference in general information between the two groups. After analyzing the puncture situation of the two groups, it was found that the average catheterization time of the observation group was shorter than that of the control group, and the difference was statistically significant. Patients in the observation group had higher success rate of one-time catheterization and catheterization success rate, and the difference was statistically significant. The incidences of occult thrombosis, phlebitis and catheter blockage in the observation group were lower than those in the control group, and the difference was statistically significant. The incidence of dominant thrombosis and bleeding at puncture point in the observation group was also lower than that in the control group, but the difference was not statistically significant.
Conclusion
The new type of medical guide wire component is effective for PICC catheterization and worthy of further promotion. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
ISSN: | 2047-783X 0949-2321 2047-783X |
DOI: | 10.1186/s40001-021-00571-1 |