Derivation and Validation of ESC-0/1-h Algorithm for High-Sensitivity Troponin T and I in Cancer Patients
The diagnostic performance of high-sensitivity cardiac troponin T/I (hs-cTnT/I) and the efficacy of the European Society of Cardiology (ESC) 0/1-h hs-cTnT/I algorithms for the early diagnosis of non-ST-elevation myocardial infarction are lower in cancer patients. The authors aimed to derive new cuto...
Saved in:
Published in | JACC. Advances (Online) Vol. 4; no. 6; p. 101821 |
---|---|
Main Authors | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
Elsevier Inc
01.06.2025
Elsevier |
Subjects | |
Online Access | Get full text |
ISSN | 2772-963X 2772-963X |
DOI | 10.1016/j.jacadv.2025.101821 |
Cover
Summary: | The diagnostic performance of high-sensitivity cardiac troponin T/I (hs-cTnT/I) and the efficacy of the European Society of Cardiology (ESC) 0/1-h hs-cTnT/I algorithms for the early diagnosis of non-ST-elevation myocardial infarction are lower in cancer patients.
The authors aimed to derive new cutoffs for ESC 0/1-h hs-cTnT/I algorithms optimized for use in patients with active or past cancer.
Patients presenting with suspected non-ST-elevation myocardial infarction to the emergency department enrolled in an international multicenter study were analyzed. Final diagnoses were centrally adjudicated by 2 independent cardiologists according to the fourth universal definition of myocardial infarction. External validation was performed in 2 independent cohorts.
Among 541 eligible cancer patients, cancer-optimized ESC 0/1-h hs-cTnT cutoffs, <8 ng/L at presentation (if chest pain onset >3 hours) or <14 ng/L if 0/1 h-delta is <3 ng/L for rule-out and ≥54 ng/L or 0/1-h delta ≥4 ng/L for rule-in, increased the efficacy vs the current cutoffs from 58.6% (95% CI: 54.4-62.7) to 68.0% (95% CI: 64.0-71.8; P < 0.001). Sensitivity and specificity remained high and comparable. Similarly, among 516 eligible patients, cancer-optimized ESC 0/1-h hs-cTnI-Architect cutoffs, <7 ng/L at presentation (if chest pain onset >3 hours) or <10 ng/L if 0/1-h delta is <3 ng/L for rule-out and ≥61 ng/L or 0/1-h delta ≥5 ng/L for rule-in, increased the efficacy vs the current cutoffs from 59.3% (95% CI: 55.0-63.5) to 78.9% (95% CI: 75.2-82.2; P < 0.001). Sensitivity and specificity again remained high and comparable. Findings were confirmed in internal and external validation cohorts (n = 130 and n = 195 patients, respectively).
Cancer-optimized ESC 0/1-h hs-cTnT/I algorithm cutoffs increased efficacy maintaining high safety.
[Display omitted] |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 These authors equally to this manuscript and should be considered first authors. |
ISSN: | 2772-963X 2772-963X |
DOI: | 10.1016/j.jacadv.2025.101821 |