三维可变翻转角快速自旋回波成像技术在颈动脉高分辨磁共振成像中的应用

目的探讨三维T2可变翻转角加权快速自旋回波成像技术(three dimensional-T2 weighted imagingsampling perfection with application optimized contrasts using different flip angle evolutions,3D-T2WISPACE)序列在颈动脉高分辨率磁共振成像中的应用价值。方法收集临床怀疑颈动脉病变患者30例,进行高分辨多对比颈动脉磁共振成像(magnetic resonance imaging,MRI),行冠状位3D-T2WI-SPACE序列并应用3D后处理软件进行斜矢状位和轴位重...

Full description

Saved in:
Bibliographic Details
Published in中国卒中杂志 Vol. 9; no. 11; pp. 911 - 916
Main Author 隋滨滨 高培毅 林燕 荆利娜 秦海强
Format Journal Article
LanguageChinese
Published 北京市神经外科研究所, 北京首都医科大学附属北京天坛医院放射科,100050%首都医科大学附属北京天坛医院神经内科 2014
Subjects
Online AccessGet full text
ISSN1673-5765
DOI10.3969/j.issn.1673-5765.2014.11.005

Cover

More Information
Summary:目的探讨三维T2可变翻转角加权快速自旋回波成像技术(three dimensional-T2 weighted imagingsampling perfection with application optimized contrasts using different flip angle evolutions,3D-T2WISPACE)序列在颈动脉高分辨率磁共振成像中的应用价值。方法收集临床怀疑颈动脉病变患者30例,进行高分辨多对比颈动脉磁共振成像(magnetic resonance imaging,MRI),行冠状位3D-T2WI-SPACE序列并应用3D后处理软件进行斜矢状位和轴位重建。比较3D-T2WI-SPACE序列和横轴位黑血T2WI序列的信噪比及图像质量,并对图像成像范围、对病变诊断信息提供的充分程度进行比较。结果 60支颈动脉中,正常13支,病变47支。其中颈动脉粥样硬化病变44支,颈动脉夹层1支,不明原因的特发性狭窄2支。30例病例图像质量评价中,3D-T2WI-SPACE序列图像质量2级5例,3级25例;T2WI序列图像质量2级4例,3级26例。3D-T2WI-SPACE序列对诊断信息提供的充分程度略优于高分辨T2WI。3D-T2WI-SPACE序列与高分辨率T2WI图像的覆盖范围分别为(114.7±22.4)mm和46 mm。3D-T2WI-SPACE序列图像与高分辨T2WI的信噪比平均值分别为15.7±3.5及22.7±14.7,差异无显著性(P=0.163)。结论 3D-T2WI-SPACE技术可作为颈动脉高分辨成像序列中的必要辅助序列。应用3D-T2WI-SPACE序列结合重建技术,可为临床诊断提供更多信息。
Bibliography:11-5434/R
Carotid;Magnetic resonance imaging;High-resolution plaque magnetic resonance imaging;Three-dimensional reconstruction
Objective To study the application value of three dimensional-T2 weighted imaging-sampling perfection with application optimized contrasts using different flip angle evolutions (3D-T2WI-SPACE) sequence in carotid high-resolution magnetic resonance imaging (MRI). Methods Thirty patients with suspected carotid disease were recruited in this study. High-resolution multicontrast MRI was performed using 3.0T MRI with a 4-channel surface carotid coil. 3D-T2WI-SPACE sequence was applied by coronal plane; and oblique saggital and axial images were reconstructed using post-processing software. Signal-to-noise ratio, image quality of 3D-T2WI-SPACE sequence and axial high-resolution T2WI sequence, as well as scan coverage and diagnostic information were compared. Results Among all sixty carotids, thirteen vessels are normal, and forty-four carotids were found plaques; one was carotid dissection;
ISSN:1673-5765
DOI:10.3969/j.issn.1673-5765.2014.11.005