Flash Glucose Monitoring and Diabetes Mellitus Induced by Immune Checkpoint Inhibitors: An Approach to Clinical Practice
Objectives. The aim of this study is to investigate in depth diabetes mellitus associated with immune checkpoint inhibitors (DM-ICIs) by analysing a case series. We also evaluated the clinical impact of flash glucose monitoring (FGM) systems in the management of this entity. Methods. We conducted an...
Saved in:
Published in | Journal of Diabetes Research Vol. 2022; pp. 1 - 16 |
---|---|
Main Authors | , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Cairo
Hindawi
04.11.2022
John Wiley & Sons, Inc Wiley |
Subjects | |
Online Access | Get full text |
ISSN | 2314-6745 2314-6753 2314-6753 |
DOI | 10.1155/2022/4508633 |
Cover
Summary: | Objectives. The aim of this study is to investigate in depth diabetes mellitus associated with immune checkpoint inhibitors (DM-ICIs) by analysing a case series. We also evaluated the clinical impact of flash glucose monitoring (FGM) systems in the management of this entity. Methods. We conducted an observational cohort study of DM-ICIs diagnosed in two hospitals in Seville (Spain). Patients with a new diagnosis of diabetes mellitus (DM) or with sudden worsening of preexisting DM after starting treatment with ICIs, with a random 5 hour-postprandial C-peptide value of <0.6 nmol/L and without possibility of subsequent withdrawal of insulin treatment, were included. Results. A total of 7 cases were identified, mostly males (n=6; 85.7%), with a mean age of 64.9 years. The mean glycated hemoglobin (HbA1c) upon diagnosis was 8.1%, with diabetic ketoacidosis (DKA) observed in 6 cases (85.7%). Subcutaneous flash glucose monitoring (FGM) systems were used in six cases, with a mean follow-up period of 42.7 weeks. During the first 90 days of use, mean average glucose was 167.5 mg/dL, with a coefficient of variation (CV) of 34.6%. The mean time in the range 70-180 mg/dL (TIR) was 59.7%, with a mean time above range (TAR) 181-250 mg/dL of 27.8% and a mean TAR>250 mg/dL of 10.2%. The mean time below range (TBR) 54-69 mg/dL was 2%, while the mean TBR<54 mg/dL was 0.3%. The mean glucose management indicator (GMI) was 7.3%. No significant differences were observed in FGM values for the following 90 days of follow-up. A progressive improvement in all parameters of glycaemic control was observed between the first month of FGM use and the sixth month of FGM use. Of note, there was a decrease in mean CV (40.6% to 34.1%, p=0.25), mean TAR 181-250 (30.3% to 26%, p=0.49), mean TAR>250 mg/dL (16.3% to 7.7%, p=0.09), mean TBR 54-69 mg/dL (5.2% to 2%, p=0.16), and mean TBR<54 mg/dL (1.8% to 0.2%, p=0.31), along with an increase in mean values of TIR 70-180 mg/dL (46.5% to 60.5%, p=0.09). The lack of statistical significance in the differences observed in the mean FGM values over the follow-up period may be related to the small sample size. Conclusion. DM-ICI is recognised by a state of sudden-onset insulinopenia, often associated with DKA. The use of FGM systems may be a valid option for the effective management of DM-ICIs and for the prevention of severe hyperglycaemic and hypoglycaemic episodes in this condition. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 ObjectType-Article-2 ObjectType-Undefined-1 ObjectType-Feature-3 content type line 23 Academic Editor: Marco Infante |
ISSN: | 2314-6745 2314-6753 2314-6753 |
DOI: | 10.1155/2022/4508633 |