Human lymphatic pumping measured in healthy and lymphoedematous arms by lymphatic congestion lymphoscintigraphy
Axillary surgery for breast cancer partially obstructs lymph outflow from the arm, chronically raising the lymphatic smooth muscle afterload. This may lead to pump failure, as in hypertensive cardiac failure, and could explain features of breast cancer treatment-related lymphoedema (BCRL) such as it...
Saved in:
Published in | The Journal of physiology Vol. 583; no. 1; pp. 271 - 285 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
Oxford, UK
The Physiological Society
15.08.2007
Blackwell Publishing Ltd Blackwell Science Inc |
Subjects | |
Online Access | Get full text |
ISSN | 0022-3751 1469-7793 1469-7793 |
DOI | 10.1113/jphysiol.2007.130401 |
Cover
Summary: | Axillary surgery for breast cancer partially obstructs lymph outflow from the arm, chronically raising the lymphatic smooth
muscle afterload. This may lead to pump failure, as in hypertensive cardiac failure, and could explain features of breast
cancer treatment-related lymphoedema (BCRL) such as its delayed onset. A new method was developed to measure human lymphatic
contractility non-invasively and test the hypothesis of contractile impairment. 99m Tc-human IgG (Tc-HIG), injected into the hand dermis, drained into the arm lymphatic system which was imaged using a gamma-camera.
Lymph transit time from hand to axilla, t transit , was 9.6 ± 7.2 min (mean ±
s.d. ) (velocity 8.9 cm min â1 ) in seven normal subjects. To assess lymphatic contractility, a sphygmomanometer cuff around the upper arm was inflated to
60 mmHg ( P cuff ) before 99m Tc-HIG injection and maintained for >> t transit . When P cuff exceeded the maximum pressure generated by the lymphatic pump ( P pump ), radiolabelled lymph was held up at the distal cuff border. P cuff was then lowered in 10 mmHg steps until 99m Tc-HIG began to flow under the cuff to the axilla, indicating P pump
â¥
P cuff . In 16 normal subjects P pump was 39 ± 14 mmHg. P pump was 38% lower in 16 women with BCRL, namely 24 ± 19 mmHg ( P
= 0.014, Student's unpaired t test), and correlated negatively with the degree of swelling (12â56%). Blood radiolabel accumulation proved an unreliable
measure of lymphatic pump function. Lymphatic congestion lymphoscintigraphy thus provided a quantitative measure of human
lymphatic contractility without surgical cut-down, and the results supported the hypothesis of lymphatic pump failure in BCRL. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 ObjectType-Article-2 ObjectType-Feature-1 |
ISSN: | 0022-3751 1469-7793 1469-7793 |
DOI: | 10.1113/jphysiol.2007.130401 |