Clinical evaluation of deep learning–based clinical target volume three-channel auto-segmentation algorithm for adaptive radiotherapy in cervical cancer

Objectives Accurate contouring of the clinical target volume (CTV) is a key element of radiotherapy in cervical cancer. We validated a novel deep learning (DL)-based auto-segmentation algorithm for CTVs in cervical cancer called the three-channel adaptive auto-segmentation network (TCAS). Methods A...

Full description

Saved in:
Bibliographic Details
Published inBMC medical imaging Vol. 22; no. 1; pp. 1 - 10
Main Authors Ma, Chen-ying, Zhou, Ju-ying, Xu, Xiao-ting, Qin, Song-bing, Han, Miao-fei, Cao, Xiao-huan, Gao, Yao-zong, Xu, Lu, Zhou, Jing-jie, Zhang, Wei, Jia, Le-cheng
Format Journal Article
LanguageEnglish
Published London BioMed Central 09.07.2022
BioMed Central Ltd
Springer Nature B.V
BMC
Subjects
Online AccessGet full text
ISSN1471-2342
1471-2342
DOI10.1186/s12880-022-00851-0

Cover

More Information
Summary:Objectives Accurate contouring of the clinical target volume (CTV) is a key element of radiotherapy in cervical cancer. We validated a novel deep learning (DL)-based auto-segmentation algorithm for CTVs in cervical cancer called the three-channel adaptive auto-segmentation network (TCAS). Methods A total of 107 cases were collected and contoured by senior radiation oncologists (ROs). Each case consisted of the following: (1) contrast-enhanced CT scan for positioning, (2) the related CTV, (3) multiple plain CT scans during treatment and (4) the related CTV. After registration between (1) and (3) for the same patient, the aligned image and CTV were generated. Method 1 is rigid registration, method 2 is deformable registration, and the aligned CTV is seen as the result. Method 3 is rigid registration and TCAS, method 4 is deformable registration and TCAS, and the result is generated by a DL-based method. Results From the 107 cases, 15 pairs were selected as the test set. The dice similarity coefficient (DSC) of method 1 was 0.8155 ± 0.0368; the DSC of method 2 was 0.8277 ± 0.0315; the DSCs of method 3 and 4 were 0.8914 ± 0.0294 and 0.8921 ± 0.0231, respectively. The mean surface distance and Hausdorff distance of methods 3 and 4 were markedly better than those of method 1 and 2. Conclusions The TCAS achieved comparable accuracy to the manual delineation performed by senior ROs and was significantly better than direct registration.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1471-2342
1471-2342
DOI:10.1186/s12880-022-00851-0