Impact of repetitive transcranial magnetic stimulation on cortical activity: a systematic review and meta-analysis utilizing functional near-infrared spectroscopy evaluation

Background Repeated transcranial magnetic stimulation (rTMS) could induce alterations in cortical excitability and promote neuroplasticity. To precisely quantify these effects, functional near-infrared spectroscopy (fNIRS), an optical neuroimaging modality adept at detecting changes in cortical hemo...

Full description

Saved in:
Bibliographic Details
Published inJournal of neuroengineering and rehabilitation Vol. 21; no. 1; pp. 108 - 14
Main Authors Chen, Shao-Yu, Tsou, Meng-Hsuan, Chen, Kuan-Yu, Liu, Yan-Ci, Lin, Meng-Ting
Format Journal Article
LanguageEnglish
Published London BioMed Central 24.06.2024
BioMed Central Ltd
BMC
Subjects
Online AccessGet full text
ISSN1743-0003
1743-0003
DOI10.1186/s12984-024-01407-9

Cover

Abstract Background Repeated transcranial magnetic stimulation (rTMS) could induce alterations in cortical excitability and promote neuroplasticity. To precisely quantify these effects, functional near-infrared spectroscopy (fNIRS), an optical neuroimaging modality adept at detecting changes in cortical hemodynamic responses, has been employed concurrently alongside rTMS to measure and tailor the impact of diverse rTMS protocols on the brain cortex. Objective This systematic review and meta-analysis aimed to elucidate the effects of rTMS on cortical hemodynamic responses over the primary motor cortex (M1) as detected by fNIRS. Methods Original articles that utilized rTMS to stimulate the M1 cortex in combination with fNIRS for the assessment of cortical activity were systematically searched across the PubMed, Embase, and Scopus databases. The search encompassed records from the inception of these databases up until April, 2024. The assessment for risk of bias was also conducted. A meta-analysis was also conducted in studies with extractable raw data. Results Among 312 studies, 14 articles were eligible for qualitative review. 7 studies were eligible for meta-analysis. A variety of rTMS protocols was employed on M1 cortex. In inhibitory rTMS, multiple studies observed a reduction in the concentration of oxygenated hemoglobin [HbO] at the ipsilateral M1, contrasted by an elevation at the contralateral M1. Meta-analysis also corroborated this consistent trend. Nevertheless, certain investigations unveiled diminished [HbO] in bilateral M1. Several studies also depicted intricate inhibitory or excitatory interplay among distinct cortical regions. Conclusion Diverse rTMS protocols led to varied patterns of cortical activity detected by fNIRS. Meta-analysis revealed a trend of increasing [HbO] in the contralateral cortices and decreasing [HbO] in the ipsilateral cortices following low frequency inhibitory rTMS. However, due to the heterogeneity between studies, further research is necessary to comprehensively understand rTMS-induced alterations in brain activity.
AbstractList Repeated transcranial magnetic stimulation (rTMS) could induce alterations in cortical excitability and promote neuroplasticity. To precisely quantify these effects, functional near-infrared spectroscopy (fNIRS), an optical neuroimaging modality adept at detecting changes in cortical hemodynamic responses, has been employed concurrently alongside rTMS to measure and tailor the impact of diverse rTMS protocols on the brain cortex. This systematic review and meta-analysis aimed to elucidate the effects of rTMS on cortical hemodynamic responses over the primary motor cortex (M1) as detected by fNIRS. Original articles that utilized rTMS to stimulate the M1 cortex in combination with fNIRS for the assessment of cortical activity were systematically searched across the PubMed, Embase, and Scopus databases. The search encompassed records from the inception of these databases up until April, 2024. The assessment for risk of bias was also conducted. A meta-analysis was also conducted in studies with extractable raw data. Among 312 studies, 14 articles were eligible for qualitative review. 7 studies were eligible for meta-analysis. A variety of rTMS protocols was employed on M1 cortex. In inhibitory rTMS, multiple studies observed a reduction in the concentration of oxygenated hemoglobin [HbO] at the ipsilateral M1, contrasted by an elevation at the contralateral M1. Meta-analysis also corroborated this consistent trend. Nevertheless, certain investigations unveiled diminished [HbO] in bilateral M1. Several studies also depicted intricate inhibitory or excitatory interplay among distinct cortical regions. Diverse rTMS protocols led to varied patterns of cortical activity detected by fNIRS. Meta-analysis revealed a trend of increasing [HbO] in the contralateral cortices and decreasing [HbO] in the ipsilateral cortices following low frequency inhibitory rTMS. However, due to the heterogeneity between studies, further research is necessary to comprehensively understand rTMS-induced alterations in brain activity.
Abstract Background Repeated transcranial magnetic stimulation (rTMS) could induce alterations in cortical excitability and promote neuroplasticity. To precisely quantify these effects, functional near-infrared spectroscopy (fNIRS), an optical neuroimaging modality adept at detecting changes in cortical hemodynamic responses, has been employed concurrently alongside rTMS to measure and tailor the impact of diverse rTMS protocols on the brain cortex. Objective This systematic review and meta-analysis aimed to elucidate the effects of rTMS on cortical hemodynamic responses over the primary motor cortex (M1) as detected by fNIRS. Methods Original articles that utilized rTMS to stimulate the M1 cortex in combination with fNIRS for the assessment of cortical activity were systematically searched across the PubMed, Embase, and Scopus databases. The search encompassed records from the inception of these databases up until April, 2024. The assessment for risk of bias was also conducted. A meta-analysis was also conducted in studies with extractable raw data. Results Among 312 studies, 14 articles were eligible for qualitative review. 7 studies were eligible for meta-analysis. A variety of rTMS protocols was employed on M1 cortex. In inhibitory rTMS, multiple studies observed a reduction in the concentration of oxygenated hemoglobin [HbO] at the ipsilateral M1, contrasted by an elevation at the contralateral M1. Meta-analysis also corroborated this consistent trend. Nevertheless, certain investigations unveiled diminished [HbO] in bilateral M1. Several studies also depicted intricate inhibitory or excitatory interplay among distinct cortical regions. Conclusion Diverse rTMS protocols led to varied patterns of cortical activity detected by fNIRS. Meta-analysis revealed a trend of increasing [HbO] in the contralateral cortices and decreasing [HbO] in the ipsilateral cortices following low frequency inhibitory rTMS. However, due to the heterogeneity between studies, further research is necessary to comprehensively understand rTMS-induced alterations in brain activity.
Background Repeated transcranial magnetic stimulation (rTMS) could induce alterations in cortical excitability and promote neuroplasticity. To precisely quantify these effects, functional near-infrared spectroscopy (fNIRS), an optical neuroimaging modality adept at detecting changes in cortical hemodynamic responses, has been employed concurrently alongside rTMS to measure and tailor the impact of diverse rTMS protocols on the brain cortex. Objective This systematic review and meta-analysis aimed to elucidate the effects of rTMS on cortical hemodynamic responses over the primary motor cortex (M1) as detected by fNIRS. Methods Original articles that utilized rTMS to stimulate the M1 cortex in combination with fNIRS for the assessment of cortical activity were systematically searched across the PubMed, Embase, and Scopus databases. The search encompassed records from the inception of these databases up until April, 2024. The assessment for risk of bias was also conducted. A meta-analysis was also conducted in studies with extractable raw data. Results Among 312 studies, 14 articles were eligible for qualitative review. 7 studies were eligible for meta-analysis. A variety of rTMS protocols was employed on M1 cortex. In inhibitory rTMS, multiple studies observed a reduction in the concentration of oxygenated hemoglobin [HbO] at the ipsilateral M1, contrasted by an elevation at the contralateral M1. Meta-analysis also corroborated this consistent trend. Nevertheless, certain investigations unveiled diminished [HbO] in bilateral M1. Several studies also depicted intricate inhibitory or excitatory interplay among distinct cortical regions. Conclusion Diverse rTMS protocols led to varied patterns of cortical activity detected by fNIRS. Meta-analysis revealed a trend of increasing [HbO] in the contralateral cortices and decreasing [HbO] in the ipsilateral cortices following low frequency inhibitory rTMS. However, due to the heterogeneity between studies, further research is necessary to comprehensively understand rTMS-induced alterations in brain activity.
Repeated transcranial magnetic stimulation (rTMS) could induce alterations in cortical excitability and promote neuroplasticity. To precisely quantify these effects, functional near-infrared spectroscopy (fNIRS), an optical neuroimaging modality adept at detecting changes in cortical hemodynamic responses, has been employed concurrently alongside rTMS to measure and tailor the impact of diverse rTMS protocols on the brain cortex. This systematic review and meta-analysis aimed to elucidate the effects of rTMS on cortical hemodynamic responses over the primary motor cortex (M1) as detected by fNIRS. Original articles that utilized rTMS to stimulate the M1 cortex in combination with fNIRS for the assessment of cortical activity were systematically searched across the PubMed, Embase, and Scopus databases. The search encompassed records from the inception of these databases up until April, 2024. The assessment for risk of bias was also conducted. A meta-analysis was also conducted in studies with extractable raw data. Among 312 studies, 14 articles were eligible for qualitative review. 7 studies were eligible for meta-analysis. A variety of rTMS protocols was employed on M1 cortex. In inhibitory rTMS, multiple studies observed a reduction in the concentration of oxygenated hemoglobin [HbO] at the ipsilateral M1, contrasted by an elevation at the contralateral M1. Meta-analysis also corroborated this consistent trend. Nevertheless, certain investigations unveiled diminished [HbO] in bilateral M1. Several studies also depicted intricate inhibitory or excitatory interplay among distinct cortical regions. Diverse rTMS protocols led to varied patterns of cortical activity detected by fNIRS. Meta-analysis revealed a trend of increasing [HbO] in the contralateral cortices and decreasing [HbO] in the ipsilateral cortices following low frequency inhibitory rTMS. However, due to the heterogeneity between studies, further research is necessary to comprehensively understand rTMS-induced alterations in brain activity.
Background Repeated transcranial magnetic stimulation (rTMS) could induce alterations in cortical excitability and promote neuroplasticity. To precisely quantify these effects, functional near-infrared spectroscopy (fNIRS), an optical neuroimaging modality adept at detecting changes in cortical hemodynamic responses, has been employed concurrently alongside rTMS to measure and tailor the impact of diverse rTMS protocols on the brain cortex. Objective This systematic review and meta-analysis aimed to elucidate the effects of rTMS on cortical hemodynamic responses over the primary motor cortex (M1) as detected by fNIRS. Methods Original articles that utilized rTMS to stimulate the M1 cortex in combination with fNIRS for the assessment of cortical activity were systematically searched across the PubMed, Embase, and Scopus databases. The search encompassed records from the inception of these databases up until April, 2024. The assessment for risk of bias was also conducted. A meta-analysis was also conducted in studies with extractable raw data. Results Among 312 studies, 14 articles were eligible for qualitative review. 7 studies were eligible for meta-analysis. A variety of rTMS protocols was employed on M1 cortex. In inhibitory rTMS, multiple studies observed a reduction in the concentration of oxygenated hemoglobin [HbO] at the ipsilateral M1, contrasted by an elevation at the contralateral M1. Meta-analysis also corroborated this consistent trend. Nevertheless, certain investigations unveiled diminished [HbO] in bilateral M1. Several studies also depicted intricate inhibitory or excitatory interplay among distinct cortical regions. Conclusion Diverse rTMS protocols led to varied patterns of cortical activity detected by fNIRS. Meta-analysis revealed a trend of increasing [HbO] in the contralateral cortices and decreasing [HbO] in the ipsilateral cortices following low frequency inhibitory rTMS. However, due to the heterogeneity between studies, further research is necessary to comprehensively understand rTMS-induced alterations in brain activity. Keywords: Repeated transcranial magnetic stimulation (rTMS), Functional near-infrared spectroscopy (fNIRS), Primary motor cortex, Cortical hemodynamics, Cortical excitability
Repeated transcranial magnetic stimulation (rTMS) could induce alterations in cortical excitability and promote neuroplasticity. To precisely quantify these effects, functional near-infrared spectroscopy (fNIRS), an optical neuroimaging modality adept at detecting changes in cortical hemodynamic responses, has been employed concurrently alongside rTMS to measure and tailor the impact of diverse rTMS protocols on the brain cortex.BACKGROUNDRepeated transcranial magnetic stimulation (rTMS) could induce alterations in cortical excitability and promote neuroplasticity. To precisely quantify these effects, functional near-infrared spectroscopy (fNIRS), an optical neuroimaging modality adept at detecting changes in cortical hemodynamic responses, has been employed concurrently alongside rTMS to measure and tailor the impact of diverse rTMS protocols on the brain cortex.This systematic review and meta-analysis aimed to elucidate the effects of rTMS on cortical hemodynamic responses over the primary motor cortex (M1) as detected by fNIRS.OBJECTIVEThis systematic review and meta-analysis aimed to elucidate the effects of rTMS on cortical hemodynamic responses over the primary motor cortex (M1) as detected by fNIRS.Original articles that utilized rTMS to stimulate the M1 cortex in combination with fNIRS for the assessment of cortical activity were systematically searched across the PubMed, Embase, and Scopus databases. The search encompassed records from the inception of these databases up until April, 2024. The assessment for risk of bias was also conducted. A meta-analysis was also conducted in studies with extractable raw data.METHODSOriginal articles that utilized rTMS to stimulate the M1 cortex in combination with fNIRS for the assessment of cortical activity were systematically searched across the PubMed, Embase, and Scopus databases. The search encompassed records from the inception of these databases up until April, 2024. The assessment for risk of bias was also conducted. A meta-analysis was also conducted in studies with extractable raw data.Among 312 studies, 14 articles were eligible for qualitative review. 7 studies were eligible for meta-analysis. A variety of rTMS protocols was employed on M1 cortex. In inhibitory rTMS, multiple studies observed a reduction in the concentration of oxygenated hemoglobin [HbO] at the ipsilateral M1, contrasted by an elevation at the contralateral M1. Meta-analysis also corroborated this consistent trend. Nevertheless, certain investigations unveiled diminished [HbO] in bilateral M1. Several studies also depicted intricate inhibitory or excitatory interplay among distinct cortical regions.RESULTSAmong 312 studies, 14 articles were eligible for qualitative review. 7 studies were eligible for meta-analysis. A variety of rTMS protocols was employed on M1 cortex. In inhibitory rTMS, multiple studies observed a reduction in the concentration of oxygenated hemoglobin [HbO] at the ipsilateral M1, contrasted by an elevation at the contralateral M1. Meta-analysis also corroborated this consistent trend. Nevertheless, certain investigations unveiled diminished [HbO] in bilateral M1. Several studies also depicted intricate inhibitory or excitatory interplay among distinct cortical regions.Diverse rTMS protocols led to varied patterns of cortical activity detected by fNIRS. Meta-analysis revealed a trend of increasing [HbO] in the contralateral cortices and decreasing [HbO] in the ipsilateral cortices following low frequency inhibitory rTMS. However, due to the heterogeneity between studies, further research is necessary to comprehensively understand rTMS-induced alterations in brain activity.CONCLUSIONDiverse rTMS protocols led to varied patterns of cortical activity detected by fNIRS. Meta-analysis revealed a trend of increasing [HbO] in the contralateral cortices and decreasing [HbO] in the ipsilateral cortices following low frequency inhibitory rTMS. However, due to the heterogeneity between studies, further research is necessary to comprehensively understand rTMS-induced alterations in brain activity.
ArticleNumber 108
Audience Academic
Author Chen, Shao-Yu
Lin, Meng-Ting
Chen, Kuan-Yu
Tsou, Meng-Hsuan
Liu, Yan-Ci
Author_xml – sequence: 1
  givenname: Shao-Yu
  surname: Chen
  fullname: Chen, Shao-Yu
  organization: Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, College of Medicine, National Taiwan University
– sequence: 2
  givenname: Meng-Hsuan
  surname: Tsou
  fullname: Tsou, Meng-Hsuan
  organization: School and Graduate Institute of Physical Therapy, College of Medicine, National Taiwan University
– sequence: 3
  givenname: Kuan-Yu
  surname: Chen
  fullname: Chen, Kuan-Yu
  organization: Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, College of Medicine, National Taiwan University
– sequence: 4
  givenname: Yan-Ci
  surname: Liu
  fullname: Liu, Yan-Ci
  email: yanciliu@ntu.edu.tw
  organization: School and Graduate Institute of Physical Therapy, College of Medicine, National Taiwan University, Physical Therapy Center, National Taiwan University Hospital, College of Medicine, National Taiwan University
– sequence: 5
  givenname: Meng-Ting
  surname: Lin
  fullname: Lin, Meng-Ting
  email: b96401093@ntu.edu.tw
  organization: Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, College of Medicine, National Taiwan University
BackLink https://www.ncbi.nlm.nih.gov/pubmed/38915003$$D View this record in MEDLINE/PubMed
BookMark eNp9kstu1DAUhiNURC_wAiyQJTZsUuzYubFBVcVlpEpsYG2dcU6CR4kdbGfQ8E68I2dmWtQiVOXmHP__59t_np047zDLXgp-KURTvY2iaBuV84IeoXidt0-yM1ErmXPO5cm99ml2HuOGGoqX6ll2KptWlPR7lv1eTTOYxHzPAs6YbLJbZCmAi4ZeFkY2weCow7CY7LSMkKx3jG7jA1VJQH67tWn3jgGLu5hwgr084NbiTwauYxMmyMHBuIs2siXZ0f6ybmD94sweRxCHEHLr-gABOxZnNCn4aPy8Y7iFcTkM-zx72sMY8cXt9yL79vHD1-vP-c2XT6vrq5vclA1Pueqh7uvSyLZShSigr6RCNJWRolCtKksQaymlkBXIojO0i3JdmrUyddmtq6KTF9nqyO08bPQc7ARhpz1YfSj4MGjYL35EXammka00xhRCVbyiIVUvuOqVgLKtkVjvj6x5WU_YGXS0u-MD6MMeZ7_rwW-1EKJVbcmJ8OaWEPyPBWPSk40GxxEc-iVqyeuCTrlqCpK-PkoHoLnRdnpCmr1cX9VtyxUv5F51-R8VXR1O1lDIekv1B4ZX99fwd_J3OSJBcxQYOrQYsNfGpsOREdmOWnC9j6w-RlZTZPUhsrola_GP9Y7-qEkeTZHEbsCgN34JlKP4mOsPMhQBfw
CitedBy_id crossref_primary_10_1177_26331055251328355
crossref_primary_10_1177_10538135241304991
crossref_primary_10_3390_biomedicines12112506
crossref_primary_10_1016_j_sleep_2024_11_030
Cites_doi 10.1016/j.clinph.2020.02.003
10.3389/fnmol.2022.887426
10.3389/fnins.2019.00084
10.1007/s10654-010-9491-z
10.1136/bmj.l4898
10.1007/s10548-009-0115-4
10.1016/s0006-3223(03)00002-7
10.1016/j.neuron.2004.12.033
10.1161/01.STR.0000231390.58967.6b
10.1016/j.neuroimage.2009.05.016
10.1111/j.1468-1331.2009.02746.x
10.1007/s00221-011-2855-0
10.1117/1.JBO.17.11.116020
10.1016/s0006-3223(98)00368-0
10.1016/j.neuroimage.2010.10.058
10.1177/0269215520972940
10.1016/s0140-6736(85)92413-4
10.1152/jn.01306.2004
10.1016/0304-3940(93)90181-J
10.1016/j.nicl.2018.101620
10.1113/jphysiol.2008.152793
10.1016/j.neuroimage.2006.04.200
10.1097/NPT.0000000000000402
10.1016/j.neulet.2017.05.039
10.1016/j.clinph.2004.02.005
10.1016/j.clinph.2007.09.124
10.1016/j.clinph.2008.02.006
10.1007/s00221-008-1601-8
10.1093/brain/118.2.429
10.1007/s00221-007-0884-5
10.1007/s00221-020-05788-w
10.1016/j.neulet.2009.03.035
10.3233/rnn-201032
10.1016/0006-8993(93)91240-S
10.1371/journal.pone.0024002
10.1016/j.clinph.2006.05.006
10.1111/ner.12337
10.1016/j.brs.2008.11.002
10.1007/s004150050536
10.1016/S0166-2236(97)01132-6
10.1097/00001756-200303240-00017
10.1016/j.jstrokecerebrovasdis.2017.09.008
10.1016/j.neubiorev.2014.12.014
10.1016/j.neuroimage.2011.03.001
10.1111/ene.13105
10.1007/s00221-007-0952-x
10.1117/1.JBO.18.6.067006
10.1016/j.brs.2011.12.004
10.3233/RNN-2010-0564
10.1016/j.neuroimage.2008.04.172
10.3390/brainsci13111609
10.1016/j.neubiorev.2017.10.006
10.3389/fnhum.2019.00090
ContentType Journal Article
Copyright The Author(s) 2024
2024. The Author(s).
COPYRIGHT 2024 BioMed Central Ltd.
Copyright_xml – notice: The Author(s) 2024
– notice: 2024. The Author(s).
– notice: COPYRIGHT 2024 BioMed Central Ltd.
DBID C6C
AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7X8
5PM
DOA
DOI 10.1186/s12984-024-01407-9
DatabaseName Springer Nature OA Free Journals (Selected full-text)
CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
PubMed Central (Full Participant titles)
DOAJ Directory of Open Access Journals
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList


MEDLINE

MEDLINE - Academic
Database_xml – sequence: 1
  dbid: C6C
  name: Springer Nature OA Free Journals
  url: http://www.springeropen.com/
  sourceTypes: Publisher
– sequence: 2
  dbid: DOA
  name: DOAJ Directory of Open Access Journals
  url: https://www.doaj.org/
  sourceTypes: Open Website
– sequence: 3
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 4
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
Engineering
Occupational Therapy & Rehabilitation
Physical Therapy
EISSN 1743-0003
EndPage 14
ExternalDocumentID oai_doaj_org_article_6488393ccc2146069644f104f41a597e
PMC11194950
A799040232
38915003
10_1186_s12984_024_01407_9
Genre Meta-Analysis
Research Support, Non-U.S. Gov't
Systematic Review
Journal Article
GeographicLocations Taiwan
GeographicLocations_xml – name: Taiwan
GrantInformation_xml – fundername: National Taiwan University Hospital
  grantid: NTUH 113-O0025, 113-N0010
GroupedDBID ---
0R~
29L
2QV
2WC
53G
5GY
5VS
7RV
7X7
88E
8FE
8FG
8FH
8FI
8FJ
AAFWJ
AAJSJ
AASML
AAWTL
ABDBF
ABJCF
ABUWG
ACGFO
ACGFS
ACIWK
ACPRK
ACUHS
ADBBV
ADRAZ
ADUKV
AENEX
AFKRA
AFPKN
AFRAH
AHBYD
AHMBA
AHYZX
ALMA_UNASSIGNED_HOLDINGS
AMKLP
AMTXH
AOIJS
AQUVI
BAPOH
BAWUL
BBNVY
BCNDV
BENPR
BFQNJ
BGLVJ
BHPHI
BMC
BPHCQ
BVXVI
C6C
CCPQU
CS3
DIK
DU5
E3Z
EBD
EBLON
EBS
ESX
F5P
FYUFA
GROUPED_DOAJ
GX1
HCIFZ
HMCUK
HYE
I-F
IAO
IHR
INH
INR
IPY
ITC
KQ8
L6V
LK8
M0T
M1P
M48
M7P
M7S
ML0
M~E
NAPCQ
O5R
O5S
OK1
OVT
P2P
PGMZT
PHGZM
PHGZT
PIMPY
PJZUB
PPXIY
PQGLB
PQQKQ
PROAC
PSQYO
PTHSS
PUEGO
RBZ
RNS
ROL
RPM
RSV
SBL
SOJ
TR2
TUS
UKHRP
WOQ
WOW
XSB
~8M
AAYXX
ALIPV
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
PMFND
7X8
5PM
ID FETCH-LOGICAL-c580t-4fa7f75c3964212af634eec6c31249455a1b333136a32dc2983b5cb4c75db62d3
IEDL.DBID M48
ISSN 1743-0003
IngestDate Wed Aug 27 01:08:28 EDT 2025
Thu Aug 21 18:33:51 EDT 2025
Fri Sep 05 06:59:44 EDT 2025
Tue Jun 17 22:09:35 EDT 2025
Tue Jun 10 21:08:18 EDT 2025
Mon Jul 21 06:08:32 EDT 2025
Thu Apr 24 23:16:23 EDT 2025
Tue Jul 01 02:20:02 EDT 2025
Sat Sep 06 07:18:50 EDT 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 1
Keywords Primary motor cortex
Cortical excitability
Repeated transcranial magnetic stimulation (rTMS)
Functional near-infrared spectroscopy (fNIRS)
Cortical hemodynamics
Language English
License 2024. The Author(s).
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c580t-4fa7f75c3964212af634eec6c31249455a1b333136a32dc2983b5cb4c75db62d3
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
ObjectType-Review-4
content type line 23
ObjectType-Undefined-3
OpenAccessLink http://journals.scholarsportal.info/openUrl.xqy?doi=10.1186/s12984-024-01407-9
PMID 38915003
PQID 3072000682
PQPubID 23479
PageCount 14
ParticipantIDs doaj_primary_oai_doaj_org_article_6488393ccc2146069644f104f41a597e
pubmedcentral_primary_oai_pubmedcentral_nih_gov_11194950
proquest_miscellaneous_3072000682
gale_infotracmisc_A799040232
gale_infotracacademiconefile_A799040232
pubmed_primary_38915003
crossref_citationtrail_10_1186_s12984_024_01407_9
crossref_primary_10_1186_s12984_024_01407_9
springer_journals_10_1186_s12984_024_01407_9
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2024-06-24
PublicationDateYYYYMMDD 2024-06-24
PublicationDate_xml – month: 06
  year: 2024
  text: 2024-06-24
  day: 24
PublicationDecade 2020
PublicationPlace London
PublicationPlace_xml – name: London
– name: England
PublicationTitle Journal of neuroengineering and rehabilitation
PublicationTitleAbbrev J NeuroEngineering Rehabil
PublicationTitleAlternate J Neuroeng Rehabil
PublicationYear 2024
Publisher BioMed Central
BioMed Central Ltd
BMC
Publisher_xml – name: BioMed Central
– name: BioMed Central Ltd
– name: BMC
References F Gilio (1407_CR12) 2009; 455
H Matsumoto (1407_CR9) 2020; 238
SH Jung (1407_CR11) 2008; 119
J Kim (1407_CR23) 2020; 38
1407_CR24
1407_CR25
AT Barker (1407_CR1) 1985; 1
1407_CR28
1407_CR29
1407_CR26
1407_CR27
A Peinemann (1407_CR5) 2004; 115
1407_CR4
1407_CR7
1407_CR6
1407_CR14
1407_CR53
C Eisenegger (1407_CR15) 2008; 42
1407_CR51
1407_CR52
A Dionísio (1407_CR8) 2018; 27
1407_CR19
R Li (1407_CR22) 2019; 13
1407_CR50
A Curtin (1407_CR21) 2019; 13
1407_CR46
AM Speer (1407_CR3) 2003; 54
S Bestmann (1407_CR16) 2008; 191
1407_CR47
1407_CR44
1407_CR45
1407_CR42
1407_CR43
1407_CR40
1407_CR41
HR Siebner (1407_CR20) 2009; 2
1407_CR48
1407_CR49
M Bortoletto (1407_CR13) 2015; 49
A Oliviero (1407_CR18) 1999; 246
G Thut (1407_CR10) 2010; 22
1407_CR35
1407_CR36
1407_CR33
1407_CR34
1407_CR31
1407_CR32
1407_CR30
DE Bohning (1407_CR17) 1999; 45
1407_CR39
1407_CR37
A Valero-Cabré (1407_CR2) 2017; 83
1407_CR38
References_xml – ident: 1407_CR7
  doi: 10.1016/j.clinph.2020.02.003
– ident: 1407_CR24
  doi: 10.3389/fnmol.2022.887426
– volume: 13
  start-page: p84
  year: 2019
  ident: 1407_CR21
  publication-title: Front Neurosci
  doi: 10.3389/fnins.2019.00084
– ident: 1407_CR26
  doi: 10.1007/s10654-010-9491-z
– ident: 1407_CR25
  doi: 10.1136/bmj.l4898
– volume: 22
  start-page: 219
  issue: 4
  year: 2010
  ident: 1407_CR10
  publication-title: Brain Topogr
  doi: 10.1007/s10548-009-0115-4
– volume: 54
  start-page: 818
  issue: 8
  year: 2003
  ident: 1407_CR3
  publication-title: Biol Psychiatry
  doi: 10.1016/s0006-3223(03)00002-7
– ident: 1407_CR6
  doi: 10.1016/j.neuron.2004.12.033
– ident: 1407_CR45
  doi: 10.1161/01.STR.0000231390.58967.6b
– ident: 1407_CR33
  doi: 10.1016/j.neuroimage.2009.05.016
– ident: 1407_CR46
  doi: 10.1111/j.1468-1331.2009.02746.x
– ident: 1407_CR29
  doi: 10.1007/s00221-011-2855-0
– ident: 1407_CR30
  doi: 10.1117/1.JBO.17.11.116020
– volume: 45
  start-page: 385
  issue: 4
  year: 1999
  ident: 1407_CR17
  publication-title: Biol Psychiatry
  doi: 10.1016/s0006-3223(98)00368-0
– ident: 1407_CR38
  doi: 10.1016/j.neuroimage.2010.10.058
– ident: 1407_CR49
  doi: 10.1177/0269215520972940
– volume: 1
  start-page: 1106
  issue: 8437
  year: 1985
  ident: 1407_CR1
  publication-title: Lancet
  doi: 10.1016/s0140-6736(85)92413-4
– ident: 1407_CR42
  doi: 10.1152/jn.01306.2004
– ident: 1407_CR19
  doi: 10.1016/0304-3940(93)90181-J
– ident: 1407_CR48
  doi: 10.1016/j.nicl.2018.101620
– ident: 1407_CR51
  doi: 10.1113/jphysiol.2008.152793
– ident: 1407_CR27
  doi: 10.1016/j.neuroimage.2006.04.200
– ident: 1407_CR40
  doi: 10.1097/NPT.0000000000000402
– ident: 1407_CR31
  doi: 10.1016/j.neulet.2017.05.039
– volume: 115
  start-page: 1519
  issue: 7
  year: 2004
  ident: 1407_CR5
  publication-title: Clin Neurophysiol
  doi: 10.1016/j.clinph.2004.02.005
– volume: 119
  start-page: 71
  issue: 1
  year: 2008
  ident: 1407_CR11
  publication-title: Clin Neurophysiol
  doi: 10.1016/j.clinph.2007.09.124
– ident: 1407_CR50
  doi: 10.1016/j.clinph.2008.02.006
– volume: 191
  start-page: 383
  issue: 4
  year: 2008
  ident: 1407_CR16
  publication-title: Exp Brain Res
  doi: 10.1007/s00221-008-1601-8
– ident: 1407_CR41
  doi: 10.1093/brain/118.2.429
– ident: 1407_CR28
  doi: 10.1007/s00221-007-0884-5
– volume: 238
  start-page: 1619
  issue: 7–8
  year: 2020
  ident: 1407_CR9
  publication-title: Exp Brain Res
  doi: 10.1007/s00221-020-05788-w
– volume: 455
  start-page: 1
  issue: 1
  year: 2009
  ident: 1407_CR12
  publication-title: Neurosci Lett
  doi: 10.1016/j.neulet.2009.03.035
– volume: 38
  start-page: 407
  issue: 6
  year: 2020
  ident: 1407_CR23
  publication-title: Restor Neurol Neurosci
  doi: 10.3233/rnn-201032
– ident: 1407_CR39
  doi: 10.1016/0006-8993(93)91240-S
– ident: 1407_CR34
  doi: 10.1371/journal.pone.0024002
– ident: 1407_CR14
  doi: 10.1016/j.clinph.2006.05.006
– ident: 1407_CR43
  doi: 10.1111/ner.12337
– volume: 2
  start-page: 58
  issue: 2
  year: 2009
  ident: 1407_CR20
  publication-title: Brain Stimul
  doi: 10.1016/j.brs.2008.11.002
– volume: 246
  start-page: 1164
  issue: 12
  year: 1999
  ident: 1407_CR18
  publication-title: J Neurol
  doi: 10.1007/s004150050536
– ident: 1407_CR44
  doi: 10.1016/S0166-2236(97)01132-6
– ident: 1407_CR4
  doi: 10.1097/00001756-200303240-00017
– volume: 27
  start-page: 1
  issue: 1
  year: 2018
  ident: 1407_CR8
  publication-title: J Stroke Cerebrovasc Dis
  doi: 10.1016/j.jstrokecerebrovasdis.2017.09.008
– volume: 49
  start-page: 114
  year: 2015
  ident: 1407_CR13
  publication-title: Neurosci Biobehav Rev
  doi: 10.1016/j.neubiorev.2014.12.014
– ident: 1407_CR53
  doi: 10.1016/j.neuroimage.2011.03.001
– ident: 1407_CR47
  doi: 10.1111/ene.13105
– ident: 1407_CR32
  doi: 10.1007/s00221-007-0952-x
– ident: 1407_CR36
  doi: 10.1117/1.JBO.18.6.067006
– ident: 1407_CR35
  doi: 10.1016/j.brs.2011.12.004
– ident: 1407_CR52
  doi: 10.3233/RNN-2010-0564
– volume: 42
  start-page: 379
  issue: 1
  year: 2008
  ident: 1407_CR15
  publication-title: NeuroImage
  doi: 10.1016/j.neuroimage.2008.04.172
– ident: 1407_CR37
  doi: 10.3390/brainsci13111609
– volume: 83
  start-page: 381
  year: 2017
  ident: 1407_CR2
  publication-title: Neurosci Biobehav Rev
  doi: 10.1016/j.neubiorev.2017.10.006
– volume: 13
  start-page: p90
  year: 2019
  ident: 1407_CR22
  publication-title: Front Hum Neurosci
  doi: 10.3389/fnhum.2019.00090
SSID ssj0034054
Score 2.4343333
SecondaryResourceType review_article
Snippet Background Repeated transcranial magnetic stimulation (rTMS) could induce alterations in cortical excitability and promote neuroplasticity. To precisely...
Repeated transcranial magnetic stimulation (rTMS) could induce alterations in cortical excitability and promote neuroplasticity. To precisely quantify these...
Background Repeated transcranial magnetic stimulation (rTMS) could induce alterations in cortical excitability and promote neuroplasticity. To precisely...
Abstract Background Repeated transcranial magnetic stimulation (rTMS) could induce alterations in cortical excitability and promote neuroplasticity. To...
SourceID doaj
pubmedcentral
proquest
gale
pubmed
crossref
springer
SourceType Open Website
Open Access Repository
Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 108
SubjectTerms Biomedical and Life Sciences
Biomedical Engineering and Bioengineering
Biomedicine
Cortical excitability
Cortical hemodynamics
Functional near-infrared spectroscopy (fNIRS)
Health aspects
Hemodynamics
Humans
Infrared spectroscopy
Magnetic brain stimulation
Motor cortex
Motor Cortex - diagnostic imaging
Motor Cortex - physiology
Neurological research
Neurology
Neurosciences
Physiological aspects
Primary motor cortex
Rehabilitation Medicine
Repeated transcranial magnetic stimulation (rTMS)
Review
Spectroscopy, Near-Infrared - methods
Testing
Transcranial Magnetic Stimulation - methods
SummonAdditionalLinks – databaseName: DOAJ Directory of Open Access Journals
  dbid: DOA
  link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1Lb9QwELZQDwgOPJZXoKBB4nEAq0nsOAm3gqgKUhFCrdSbZTtOqdTNVrvphf_Ef2TGcbabIpUL0iqHtSP58c0r9nzD2CvbpKJyhaXbU5ZKmCleeWu4zFPpitYYGdKjD76p_SP59bg43ij1RXfCBnrgYeF2FCJM1MI5RyWoU1WjAW8xhmhlZtAZ9qR90zodg6lBBwt0Q-SYIlOpnRVatUpytEecIoqS1xMzFNj6_9bJG0bp6oXJK6emwRjt3WN3ohcJu8Po77Mbvpux2xvcgjN28yCems_Y600qYTgceATgDfyYsHTP2N3vcdPGPg_Y7y8hixIWLSz9OWWkoXaEngycwweCF-bmpKNMSEBlMY_FwAB_GNaG7-RAqRNUoeIDGLgkjoYhaQZM18Dc94abSI8CKApnp79wEkBGN466Q4nkKA1LujAPIT-UeDgXOJFLwvKH7Gjv8-GnfR4rPHBXVGnPZWvKtiycqCnfNjetEtJ7p5ygmtiyKExmhRCZUEbkjcNNFLZwVrqyaKzKG_GIbXWLzj9h0Dh0fL0vrW0RX05adMRVphrUaEaVTiYsGzdcu7iwVIXjTIcwqFJ6AIlGkOgAEl0n7N36nfOB_OPa3h8JR-ueRNwd_kA46whn_S84J-wtoVCTesHhOROzJHCSRNSld0t0HzDmF3nCtic9US24SfPLEceamuguXecXFyuNWj3kZ1XY5_GA6_WY6dS6QPlJWDVB_GRS05bu9GdgJUejWWO0nSbs_SgcOurD1TWr9vR_rNozdisPwq14LrfZVr-88M_RWezti6AX_gDod2cy
  priority: 102
  providerName: Directory of Open Access Journals
– databaseName: Springer Nature OA Free Journals (Selected full-text)
  dbid: C6C
  link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1LbxMxEB5BkRAceITXQkFG4nGgFtn1YzfcSkRVkIoQaqXeLNvrhUrNpkrSC_-J_8iM15tmC6qEFOUQz0r2-vM3ntjzDcArV49F5ZWj21OOSphpXgVnuSzG0qvGWhnTow--6v0j-eVYHSeZHMqF2Ty_zyv9fon-qJIcPQmnWKDkk-twQyHxEpqnetqzrsCNh-yTYv753MDxRH3-v1l4ww1dviJ56Zw0up-9e3An7RvZbjfR9-FaaEdwe0NNcAQ3D9I5-Qheb4oHs8NOOYC9Yd8HutwjuPstTVNv8wB-f455k2zesEU4oxw05EO2Ipfm8Qvhymb2R0u5jwzpYZbKfzH8YCAb_xlnlCxBNSk-MMsupKJZlybDbFuzWVhZbpMgCkPwn578wkEwcrOp1y2uQY74X9AVeRYzQkl5c44DuZAofwhHe58Op_s81XTgXlXjFZeNLZtSeTGhDNvCNlrIELz2gqpgS6Vs7oQQudBWFLXHSRROeSd9qWqni1o8gq123oYnwGqPW90QSucaRJSXDrfeOtc1cpjVpZcZ5P2EG59eLNXdODUx8Km06UBiECQmgsRMMni3fuask_u40voj4WhtSVLd8QdEsEkr32ikSDER3nuqoT7WOHDZYBDcyNxiNBcyeEsoNEQo2D1vU14EDpKkucxuiRsGjPJFkcH2wBKJwA-aX_Y4NtREt-faMD9fGuTxmJFVoc3jDtfrPtM5tcL1k0E1QPxgUMOW9uRn1CFHNznB-HqcwU6_OExiwOUVb-3p_5k_g1tFXMaaF3IbtlaL8_AcN4Ir9yIywB_0yFlH
  priority: 102
  providerName: Springer Nature
Title Impact of repetitive transcranial magnetic stimulation on cortical activity: a systematic review and meta-analysis utilizing functional near-infrared spectroscopy evaluation
URI https://link.springer.com/article/10.1186/s12984-024-01407-9
https://www.ncbi.nlm.nih.gov/pubmed/38915003
https://www.proquest.com/docview/3072000682
https://pubmed.ncbi.nlm.nih.gov/PMC11194950
https://doaj.org/article/6488393ccc2146069644f104f41a597e
Volume 21
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV1ba9swFD70AqV72CW7eeuCBrs8rN4SS5adwRhtaNYNWkppIW9CkuWukDhdksK2_7T_uHNkO427rhAMsWXQ5Vwtfd8BeGWyDk9tbOj0lKESZjJMndGhiDrCxrnWwsOjDw7l_qn4NoyHK1CXO6omcHZjakf1pE6no_c_f_z6jAr_ySt8Kj_M0GelIkRvE1K-kIS9VVj3-0V0lE8sdhU4BieiBs7c-N4mbNC-Xdypa2hVfsrT-f9rtJe81vUTlde2Vb23GtyHu1WYyXZKuXgAK65owZ0l8sEWbBxU2-oteL3MNcxOSqIB9oYdN2i8W3DvqFrVus1D-PPVwyzZJGdTd0GQNTSfbE4e0OIFpZuN9VlBUEmG1mRcVQtj-MO8139IZ4StoBIWH5lmV8zSrETVMF1kbOzmOtQVfwpDXRmd_8ZBMPLKVa8LVNkQF3BKJ-qZB5ASUecEB3LFaP4ITgd7J_39sCoBEdo47cxDkeskT2LLewTIjXQuuXDOSsupaLaIY901nPMul5pHmcX15Ca2RtgkzoyMMv4Y1opJ4Z4CyyxGxs4lxuQogFYYjNRlV2Zo8rRMrAigWy-4stXEUpmOkfJ5UipVKS8K5UV5eVG9AN4t3rko2UFubb1LcrRoScze_sZkeqYqQ6EkWlTe49ZaKrnekThwkWPOnIuuxuTPBfCWpFCRRmD3rK5gFDhIYvJSOwnGFwIjsSiArUZLtBu28fhlLceKHtFhu8JNLmcKzb4HcKXY5kkp14s-1-oRQNqQ-Magmk-K8--ethy9ag_T8U4A27VyqFrfb5m1Z__tw3PYjLzyyjASW7A2n166Fxgizk0bVpNhgtd08KUN67t7h0fH-K8v-23_0aXt7cJfz1xolg
linkProvider Scholars Portal
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1bb9MwFD6CIXF54FJugQFG4vIAEU3sOClvo2LqYJ0Q6qS9WbbjwKQ1ndrshf_Ef-Qcx-magSYhVX2oTyQ7_nyOT-3vOwCvTDnkhc0M3Z4yVMJMxoUzOhbpUNis0lp4evT0QE4OxZej7CjI5BAXZvP8PinkhxXGo0LEGEliygXyeHQVrtHJJenkj-W487ocNx6iI8X887le4PH6_H974Y0wdPGK5IVzUh9-du_C7bBvZDvtRN-DK64ewK0NNcEBXJ-Gc_IBvN4UD2azVjmAvWHfe7rcA7jzLUxTZ3Mffu953iRbVGzpTomDhv6QNRTSLH4hXNlc_6iJ-8jQPcxD-S-GH0xk_T_jjMgSVJPiI9PsXCqatTQZpuuSzV2jYx0EURiC_-T4Fw6CUZgNva5xDcaI_yVdkWeeEUrKmwscyLlE-QM43P08G0_iUNMhtlkxbGJR6bzKM8tHxLBNdSW5cM5Ky6kKtsgynRjOecKl5mlpcRK5yawRNs9KI9OSP4StelG7x8BKi1td53JjKkSUFQa33jKRJfowLXMrIki6CVc2vFiqu3GifOJTSNWCRCFIlAeJGkXwbv3MaSv3can1J8LR2pKkuv0PiGAVVr6S6CL5iFtrqYb6UOLARYVJcCUSjdmci-AtoVCRQ8HuWR14EThIkuZSOzluGDDL52kE2z1LdAS21_yyw7GiJro9V7vF2UqhH_eMrAJtHrW4XveZzqkzXD8RFD3E9wbVb6mPf3odcgyTI8yvhxG87xaHCh5wdclbe_J_5i_gxmQ23Vf7ewdfn8LN1C9pGadiG7aa5Zl7hpvCxjz33uAPWvxcNg
linkToPdf http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1bb9MwFLZgkyZ44FIuCwwwEpeHYa2NHSfhrVyqrbBpgk3am2U7zjZpTas2e-E_8R85x3G6ZqBJSFUf6hPJjs-19vcdQt6Yos8zmxi8PWWwhZlkmTOaibgvbFJqLTw8ev9A7h6L8UlysoLi97fd2yPJBtOALE1VvTMrysbEM7mzgCiVCQbxhWGFkLL8NlnPkjyH8mt9OBz_HLfemENCIlqwzD-f7AQkz9v_t3deCU_Xr05eOz_1YWn0gNwL-SQdNgrwkNxyVY_cXWEZ7JGN_XB-3iNvV0mF6VHDKEDf0R8dvu4euX8Ytq-VeUR-73k8JZ2WdO5miE0DP0lrDHUWvkCN6USfVoiJpOA2JqEtGIUPFLj-H3OKIArsVfGRanpFIU0b-AzVVUEnrtZMB6IUCkZxcf4LFkEx_IZZV2CbDOxijlfnqUeKIiPnFBZyRV3-mByPvh593mWh1wOzSdavmSh1WqaJ5Tkib2NdSi6cs9Jy7I4tkkQPDOd8wKXmcWFhE7lJrBE2TQoj44I_IWvVtHKbhBYWUmDnUmNK0DQrDKTkciAL8G1aplZEZNBuuLLhxWI_jgvlC6JMqkZJFCiJ8kqi8ohsL5-ZNTQgN0p_Qj1aSiKFt_9hOj9VwSMoCa6T59xai73V-xIWLkoojksx0FDluYi8Ry1U6GhgelYHvAQsEim71DCFRAKqfx5HZKsjCQ7CdoZft3qscAhv1VVuerlQ4N89UisDmaeNXi_njOfXCdhPRLKOxncW1R2pzs88PzmEzxzq7n5EPrTGoYJnXNzw1p79n_grsnH4ZaS-7x18e07uxN6iJYvFFlmr55fuBeSKtXkZ3MEfjURl9A
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Impact+of+repetitive+transcranial+magnetic+stimulation+on+cortical+activity%3A+a+systematic+review+and+meta-analysis+utilizing+functional+near-infrared+spectroscopy+evaluation&rft.jtitle=Journal+of+neuroengineering+and+rehabilitation&rft.au=Chen%2C+Shao-Yu&rft.au=Tsou%2C+Meng-Hsuan&rft.au=Chen%2C+Kuan-Yu&rft.au=Liu%2C+Yan-Ci&rft.date=2024-06-24&rft.eissn=1743-0003&rft.volume=21&rft.issue=1&rft.spage=108&rft_id=info:doi/10.1186%2Fs12984-024-01407-9&rft_id=info%3Apmid%2F38915003&rft.externalDocID=38915003
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1743-0003&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1743-0003&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1743-0003&client=summon