Visual analysis of high density EEG: As good as electrical source imaging?

•Visual analysis of HD-EEG is an excellent tool to explore the epileptogenic focus.•ESI remains the gold standard for presurgical evaluation of the cortical source.•ESI at 50% slope/ESI at peak discordance could predict worse surgical outcome. In this study, we sought to determine whether visual ana...

Full description

Saved in:
Bibliographic Details
Published inClinical neurophysiology practice Vol. 5; pp. 16 - 22
Main Authors Toscano, Gianpaolo, Carboni, Margherita, Rubega, Maria, Spinelli, Laurent, Pittau, Francesca, Bartoli, Andrea, Momjian, Shahan, Manni, Raffaele, Terzaghi, Michele, Vulliemoz, Serge, Seeck, Margitta
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier B.V 01.01.2020
Elsevier
Subjects
Online AccessGet full text
ISSN2467-981X
2467-981X
DOI10.1016/j.cnp.2019.09.002

Cover

More Information
Summary:•Visual analysis of HD-EEG is an excellent tool to explore the epileptogenic focus.•ESI remains the gold standard for presurgical evaluation of the cortical source.•ESI at 50% slope/ESI at peak discordance could predict worse surgical outcome. In this study, we sought to determine whether visual analysis of high density EEG (HD-EEG) would provide similar localizing information comparable to electrical source imaging (ESI). HD-EEG (256 electrodes) recordings from 20 patients suffering from unifocal, drug-resistant epilepsy (13 women, mean age 29.1 ± 2.62 years, 11 with temporal lobe epilepsy) were examined. In the visual analysis condition, we identified the 5 contacts with maximal spike amplitude and determined their localization with respect to the underlying cortex. ESI was computed using the LAURA algorithm of the averaged spikes in the patient’s individual MRI. We considered the localization “correct” if all 5 contacts were concordant with the resection volume underneath or if ESI was located within the resection as determined by the postoperative MRI. Twelve patients were postoperatively seizure-free (Engel Class IA), while the remaining eight were in class IB to IV. Visual analysis and ESI showed sensitivity of 58% and 75%, specificity of 75% and 87%, and accuracy of 65% and 80%, respectively. In 70% of cases, visual analysis and ESI provided concordant results. Localization of the electrodes with maximal spike amplitude provides very good estimation of the localization of the underlying source. However, ESI has a higher accuracy and adds 3D information; therefore, it should remain the tool of choice for presurgical evaluation. The present study proposes the possibility to analyze HD-EEG visually, in tandem with ESI or alone, if ESI is not accessible.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2467-981X
2467-981X
DOI:10.1016/j.cnp.2019.09.002