Accurate Detection of Low Levels of Fluorescence Emission in Autofluorescent Background: Francisella-Infected Macrophage Cells

Cellular autofluorescence, though ubiquitous when imaging cells and tissues, is often assumed to be small in comparison to the signal of interest. Uniform estimates of autofluorescence intensity obtained from separate control specimens are commonly employed to correct for autofluorescence. While the...

Full description

Saved in:
Bibliographic Details
Published inMicroscopy and microanalysis Vol. 16; no. 4; pp. 478 - 487
Main Authors Davis, Ryan W., Timlin, Jerilyn A., Kaiser, Julia N., Sinclair, Michael B., Jones, Howland D.T., Lane, Todd W.
Format Journal Article
LanguageEnglish
Published New York, USA Cambridge University Press 01.08.2010
Oxford University Press
Subjects
Online AccessGet full text
ISSN1431-9276
1435-8115
1435-8115
DOI10.1017/S1431927610000322

Cover

More Information
Summary:Cellular autofluorescence, though ubiquitous when imaging cells and tissues, is often assumed to be small in comparison to the signal of interest. Uniform estimates of autofluorescence intensity obtained from separate control specimens are commonly employed to correct for autofluorescence. While these may be sufficient for high signal-to-background applications, improvements in detector and probe technologies and introduction of spectral imaging microscopes have increased the sensitivity of fluorescence imaging methods, exposing the possibility of effectively probing the low signal-to-background regime. With spectral imaging, reliable monitoring of signals near or even below the noise levels of the microscope is possible if compensation for autofluorescence and background signals can be performed accurately. We demonstrate the importance of accurate autofluorescence modeling and the utility of spectral imaging and multivariate analysis methods using a case study focusing on fluorescence confocal spectral imaging of host-pathogen interactions. In this application fluorescent proteins are produced when Francisella novicida invade host macrophage cells. The resulting analyte signal is spectrally overlapped and typically weaker than the cellular autofluorescence. In addition to discussing the advantages of spectral imaging for following pathogen invasion, we present the spectral properties and cellular origin of macrophage autofluorescence.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ObjectType-Article-2
ObjectType-Feature-1
ISSN:1431-9276
1435-8115
1435-8115
DOI:10.1017/S1431927610000322