Comparison of the Test-Retest Reliability of the Balance Computerized Adaptive Test and a Computerized Posturography Instrument in Patients With Stroke

To compare the test-retest reliabilities of the scores of the Balance Computerized Adaptive Test (CAT) and the Biodex Balance System in patients with stroke. A repeated-measures design (at a 1-wk interval) was used to examine the test-retest reliabilities of the scores of the Balance CAT and the Bio...

Full description

Saved in:
Bibliographic Details
Published inArchives of physical medicine and rehabilitation Vol. 95; no. 8; pp. 1477 - 1483
Main Authors Chen, Chia-Hsin, Lin, Shih-Feng, Yu, Wan-Hui, Lin, Jau-Hong, Chen, Hao-Ling, Hsieh, Ching-Lin
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.08.2014
Subjects
Online AccessGet full text
ISSN0003-9993
1532-821X
1532-821X
DOI10.1016/j.apmr.2014.03.005

Cover

More Information
Summary:To compare the test-retest reliabilities of the scores of the Balance Computerized Adaptive Test (CAT) and the Biodex Balance System in patients with stroke. A repeated-measures design (at a 1-wk interval) was used to examine the test-retest reliabilities of the scores of the Balance CAT and the Biodex Balance System. One rehabilitation unit in a local hospital. Patients (N=50) with stroke for more than 6 months and undergoing outpatient rehabilitation completed the Balance CAT and the eyes open (EO)/closed (EC) tests, but only 17 patients finished the Limit of Stability (LOS) test because they were unable to reach all the targets. Not applicable. The Balance CAT and 2 computerized tests of the Biodex Balance System, namely the EO/EC test and the LOS, were used to evaluate balance function. The test-retest reliabilities of the scores of the Balance CAT (Pearson r=.92, minimal detectable change [MDC] percent=12.8%) was excellent. Those of the EO/EC and LOS tests were poor to good (Pearson r=.56–.85, MDC%=50.8%–126.9%). The test-retest reliabilities of the scores of the Balance CAT were sufficient for assessing balance function in patients with stroke. Moreover, the test-retest reliabilities of the scores of the Balance CAT, one of the functional balance measures, were superior to those of the Biodex Balance System, 1 type of computerized posturography instrument. Therefore, the Balance CAT may be a more reliable measure for clinicians and researchers to use in assessing the balance function of patients with stroke for more than 6 months.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:0003-9993
1532-821X
1532-821X
DOI:10.1016/j.apmr.2014.03.005