Model predictive filtering MR thermometry: Effects of model inaccuracies, k-space reduction factor, and temperature increase rate

Purpose Evaluate effects of model parameter inaccuracies (thermal conductivity, k, and ultrasound power deposition density, Q), k‐space reduction factor (R), and rate of temperature increase ( T˙) in a thermal model‐based reconstruction for MR‐thermometry during focused‐ultrasound heating. Methods S...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 75; no. 1; pp. 207 - 216
Main Authors Odéen, Henrik, Todd, Nick, Dillon, Christopher, Payne, Allison, Parker, Dennis L.
Format Journal Article
LanguageEnglish
Published United States Blackwell Publishing Ltd 01.01.2016
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text
ISSN0740-3194
1522-2594
1522-2594
DOI10.1002/mrm.25622

Cover

More Information
Summary:Purpose Evaluate effects of model parameter inaccuracies (thermal conductivity, k, and ultrasound power deposition density, Q), k‐space reduction factor (R), and rate of temperature increase ( T˙) in a thermal model‐based reconstruction for MR‐thermometry during focused‐ultrasound heating. Methods Simulations and ex vivo experiments were performed to investigate the accuracy of the thermal model and the model predictive filtering (MPF) algorithm for varying R and T˙, and their sensitivity to errors in k and Q. Ex vivo data was acquired with a segmented EPI pulse sequence to achieve large field‐of‐view (192 × 162 × 96 mm) four‐dimensional temperature maps with high spatiotemporal resolution (1.5 × 1.5 × 2.0 mm, 1.7 s). Results In the simulations, 50% errors in k and Q resulted in maximum temperature root mean square errors (RMSE) of 6°C for model only and 3°C for MPF. Using recently developed methods, estimates of k and Q were accurate to within 3%. The RMSE between MPF and true temperature increased with R and T˙. In the ex vivo study the RMSE remained below 0.7°C for R ranging from 4 to 12 and T˙ of 0.28–0.75°C/s. Conclusion Errors in MPF temperatures occur due to errors in k and Q. These MPF temperature errors increase with increase in R and T˙, but are smaller than those obtained using the thermal model alone. Magn Reson Med 75:207–216, 2016. © 2015 Wiley Periodicals, Inc.
Bibliography:The Ben B. and Iris M. Margolis Foundation
ark:/67375/WNG-95SQPB4B-L
NIH - No. F32 EB012917-02; No. R01s EB013433; No. CA134599; No. CA172787
Siemens Healthcare
The Focused Ultrasound Surgery Foundation
istex:CDB843CCBFAF75D44F99A6CE1AA6936D73D767D5
ArticleID:MRM25622