Postoperative Migration of an Edwards-SAPIEN XT Mitral Valve-in-Valve Treated With Direct Vision Implantation During Beating-Heart Bypass
Transcatheter valve-in-valve mitral valve replacement provides treatment options to high-risk patients but is subject to its own complications. We present the migration of a transcatheter balloon-expandable Edwards-SAPIEN XT valve (Edwards Lifesciences, Irvine, CA) within a previously implanted surg...
Saved in:
Published in | The Annals of thoracic surgery Vol. 101; no. 3; pp. 1182 - 1185 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
Netherlands
Elsevier Inc
01.03.2016
|
Subjects | |
Online Access | Get full text |
ISSN | 0003-4975 1552-6259 1552-6259 |
DOI | 10.1016/j.athoracsur.2015.04.145 |
Cover
Summary: | Transcatheter valve-in-valve mitral valve replacement provides treatment options to high-risk patients but is subject to its own complications. We present the migration of a transcatheter balloon-expandable Edwards-SAPIEN XT valve (Edwards Lifesciences, Irvine, CA) within a previously implanted surgical Carpentier-Edwards valve (Edwards Lifesciences) and our novel approach to its treatment. |
---|---|
Bibliography: | ObjectType-Case Study-2 SourceType-Scholarly Journals-1 ObjectType-Feature-4 content type line 23 ObjectType-Report-1 ObjectType-Article-3 |
ISSN: | 0003-4975 1552-6259 1552-6259 |
DOI: | 10.1016/j.athoracsur.2015.04.145 |