Comparison of subject-specific musculoskeletal model calibration strategies on muscle force and fatigue estimation

Muscle force and fatigue modeling and simulation are powerful tools for rehabilitation, sports performance, ergonomics, and injury prevention. However, their accuracy is challenged by dynamic mechanical and physiological factors. Since musculoskeletal models are typically derived from cadaver data a...

Full description

Saved in:
Bibliographic Details
Published inJournal of neuroengineering and rehabilitation Vol. 22; no. 1; pp. 156 - 18
Main Authors Michaud, Florian, Márquez, Gonzalo, Giraldez-García, Manuel A., Cuadrado, Javier
Format Journal Article
LanguageEnglish
Published London BioMed Central 10.07.2025
BioMed Central Ltd
BMC
Subjects
Online AccessGet full text
ISSN1743-0003
1743-0003
DOI10.1186/s12984-025-01691-z

Cover

More Information
Summary:Muscle force and fatigue modeling and simulation are powerful tools for rehabilitation, sports performance, ergonomics, and injury prevention. However, their accuracy is challenged by dynamic mechanical and physiological factors. Since musculoskeletal models are typically derived from cadaver data and scaled to individuals, careful subject-specific calibration is recommended to achieve accurate simulation results. This study investigates how different muscle models and calibration strategies affect the accuracy of muscle force estimation at the elbow level. Two models—a simplified static model and a rigid-tendon Hill-type model—were compared. Several calibration approaches were tested using isometric and isokinetic measurements to identify the parameters that most enhance model performance. The models were used to estimate muscle forces, and their outputs were compared to experimental data collected from seventeen healthy subjects. In the first phase, estimations were made during short maximal voluntary contractions (MVCs) without fatigue, in order to isolate muscle force from fatigue effects. In the second phase, the calibrated parameters from each strategy were used to estimate muscle forces and fatigue during a short-duration, high-intensity dynamic exercise by incorporating a muscle fatigue model. The highest accuracy was achieved with the Hill-type model, which involved refining individual muscle length and force parameters based on concentric and eccentric MVCs and adjusting two parameters of the force–velocity relationship. However, incorporating subject-specific muscle fatigue parameters did not significantly improve force estimation under fatigue conditions.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1743-0003
1743-0003
DOI:10.1186/s12984-025-01691-z