Comparison of Multimaterial Decomposition Fat Fraction with DECT and Proton Density Fat Fraction with IDEAL IQ MRI for Quantification of Liver Steatosis in a Population Exposed to Chemotherapy

Introduction: Oncologic patients who develop chemotherapy-associated liver injury (CALI) secondary to chemotherapy treatment tend to have worse outcomes. Biopsy remains the gold standard for the diagnosis of hepatic steatosis. The purpose of this article is to compare 2 alternatives: Proton-Density-...

Full description

Saved in:
Bibliographic Details
Published inDose-response Vol. 19; no. 2; p. 1559325820984938
Main Authors Corrias, Giuseppe, Erta, Marco, Sini, Marcello, Sardu, Claudia, Saba, Luca, Mahmood, Usman, Huicochea Castellanos, Sandra, Bates, David, Mondanelli, Nicola, Thomsen, Brian, Carollo, Gabriella, Sawan, Peter, Mannelli, Lorenzo
Format Journal Article
LanguageEnglish
Published Los Angeles, CA SAGE Publications 01.04.2021
SAGE PUBLICATIONS, INC
SAGE Publishing
Subjects
Online AccessGet full text
ISSN1559-3258
1559-3258
DOI10.1177/1559325820984938

Cover

More Information
Summary:Introduction: Oncologic patients who develop chemotherapy-associated liver injury (CALI) secondary to chemotherapy treatment tend to have worse outcomes. Biopsy remains the gold standard for the diagnosis of hepatic steatosis. The purpose of this article is to compare 2 alternatives: Proton-Density-Fat-Fraction (PDFF) MRI and MultiMaterial-Decomposition (MMD) DECT. Materials and Methods: 49 consecutive oncologic patients treated with Chemotherapy underwent abdominal DECT and abdominal MRI within 2 weeks of each other. Two radiologists tracked Regions of Interest independently both in the PDFF fat maps and in the MMD DECT fat maps. Non-parametric exact Wilcoxon signed rank test and Cohen’s K were used to compare the 2 sequences and to evaluate the agreement. Results: There was no statistically significant difference in the fat fraction measured as a continuous value between PDFF and DECT between 2 readers. Within the same imaging method (PDFF) the degree of agreement based on the k coefficient between reader 1 and reader 2 is 0.88 (p-value < 0.05). Similarly, for single-source DECT(ssDECT) the degree of agreement based on the k coefficient between reader 1 and reader 2 is 0.97 (p-value < 0.05). Conclusions: The results of this study demonstrate that the hepatic fat fraction of ssDECT with MMD are not significantly different from PDFF. This could be an advantage in an oncological population that undergoes serial CT scans for follow up of chemotherapy response.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1559-3258
1559-3258
DOI:10.1177/1559325820984938