Using technology to improve reconnection to remote monitoring in cardiac implantable electronic device patients

Remote monitoring (RM) of cardiac implantable electronic device (CIED) patients is now considered standard of care. However, a fundamental requirement of RM is continuous connectivity between the patient’s implanted device and the CIED manufacturer’s central server. This study examined the rate of R...

Full description

Saved in:
Bibliographic Details
Published inCardiovascular digital health journal Vol. 5; no. 1; pp. 1 - 7
Main Authors Durand, Julien, Bonnet, Jean-Luc, Lazarus, Arnaud, Taieb, Jérôme, Rosier, Arnaud, Mittal, Suneet
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.02.2024
Elsevier
Subjects
Online AccessGet full text
ISSN2666-6936
2666-6936
DOI10.1016/j.cvdhj.2023.11.020

Cover

More Information
Summary:Remote monitoring (RM) of cardiac implantable electronic device (CIED) patients is now considered standard of care. However, a fundamental requirement of RM is continuous connectivity between the patient’s implanted device and the CIED manufacturer’s central server. This study examined the rate of RM disconnections in CIED recipients and the impact of short message service (SMS) to facilitate reconnections. Using a platform that collects RM data from CIED manufacturers, we retrospectively examined the disconnection and reconnection events in 6085 patients from 20 medical centers. Each medical center reported their usual practice regarding RM disconnections, which consisted of either an automatic SMS from the platform to patients who were disconnected for 2 weeks or the standard of care (SC) of a phone call to patients. During a 1-year period, 43% of patients had at least 1 disconnection. Half of these patients experienced multiple disconnections. The use of SMS reduced the time to reconnection by 43% in comparison to SC. The median time to reconnect a disconnected patient was 11.0 [3.2, 29.0] days for SC vs 6.3 [1.3, 22.0] days for SMS (P < .0001). Furthermore, there was a high rate of reconnections within the first 48 hours of the SMS message, which was nearly double that in the SC arm. This study demonstrates the feasibility of an automatic system to deliver an SMS to patients with a disconnected CIED to facilitate early reconnection to RM.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2666-6936
2666-6936
DOI:10.1016/j.cvdhj.2023.11.020