Using neutrosophic graph cut segmentation algorithm for qualified rendering image selection in thyroid elastography video

Recently, elastography has become very popular in clinical investigation for thyroid cancer detection and diagnosis. In elastogram, the stress results of the thyroid are displayed using pseudo colors. Due to variation of the rendering results in different frames, it is difficult for radiologists to...

Full description

Saved in:
Bibliographic Details
Published inHealth information science and systems Vol. 5; no. 1; p. 8
Main Authors Guo, Yanhui, Jiang, Shuang-Quan, Sun, Baiqing, Siuly, Siuly, Şengür, Abdulkadir, Tian, Jia-Wei
Format Journal Article
LanguageEnglish
Published Cham Springer International Publishing 27.10.2017
BioMed Central Ltd
Subjects
Online AccessGet full text
ISSN2047-2501
2047-2501
DOI10.1007/s13755-017-0032-y

Cover

More Information
Summary:Recently, elastography has become very popular in clinical investigation for thyroid cancer detection and diagnosis. In elastogram, the stress results of the thyroid are displayed using pseudo colors. Due to variation of the rendering results in different frames, it is difficult for radiologists to manually select the qualified frame image quickly and efficiently. The purpose of this study is to find the qualified rendering result in the thyroid elastogram. This paper employs an efficient thyroid ultrasound image segmentation algorithm based on neutrosophic graph cut to find the qualified rendering images. Firstly, a thyroid ultrasound image is mapped into neutrosophic set, and an indeterminacy filter is constructed to reduce the indeterminacy of the spatial and intensity information in the image. A graph is defined on the image and the weight for each pixel is represented using the value after indeterminacy filtering. The segmentation results are obtained using a maximum-flow algorithm on the graph. Then the anatomic structure is identified in thyroid ultrasound image. Finally the rendering colors on these anatomic regions are extracted and validated to find the frames which satisfy the selection criteria. To test the performance of the proposed method, a thyroid elastogram dataset is built and totally 33 cases were collected. An experienced radiologist manually evaluates the selection results of the proposed method. Experimental results demonstrate that the proposed method finds the qualified rendering frame with 100% accuracy. The proposed scheme assists the radiologists to diagnose the thyroid diseases using the qualified rendering images.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2047-2501
2047-2501
DOI:10.1007/s13755-017-0032-y