Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use

Introduction To investigate whether respiratory variation of inferior vena cava diameter (cIVC) predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure (ACF). Methods Forty patients with ACF and spontaneous breathing were included. Response to fluid challenge...

Full description

Saved in:
Bibliographic Details
Published inCritical care (London, England) Vol. 16; no. 5; p. R188
Main Authors Muller, Laurent, Bobbia, Xavier, Toumi, Mehdi, Louart, Guillaume, Molinari, Nicolas, Ragonnet, Benoit, Quintard, Hervé, Leone, Marc, Zoric, Lana, Lefrant, Jean Yves
Format Journal Article
LanguageEnglish
Published London BioMed Central 08.10.2012
BioMed Central Ltd
Subjects
Online AccessGet full text
ISSN1364-8535
1466-609X
1364-8535
1466-609X
DOI10.1186/cc11672

Cover

More Information
Summary:Introduction To investigate whether respiratory variation of inferior vena cava diameter (cIVC) predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure (ACF). Methods Forty patients with ACF and spontaneous breathing were included. Response to fluid challenge was defined as a 15% increase of subaortic velocity time index (VTI) measured by transthoracic echocardiography. Inferior vena cava diameters were recorded by a subcostal view using M Mode. The cIVC was calculated as follows: (Dmax - Dmin/Dmax) × 100 and then receiver operating characteristic (ROC) curves were generated for cIVC, baseline VTI, E wave velocity, E/A and E/Ea ratios. Results Among 40 included patients, 20 (50%) were responders (R). The causes of ACF were sepsis ( n = 24), haemorrhage ( n = 11), and dehydration ( n = 5). The area under the ROC curve for cIVC was 0.77 (95% CI: 0.60-0.88). The best cutoff value was 40% (Se = 70%, Sp = 80%). The AUC of the ROC curves for baseline E wave velocity, VTI, E/A ratio, E/Ea ratio were 0.83 (95% CI: 0.68-0.93), 0.78 (95% CI: 0.61-0.88), 0.76 (95% CI: 0.59-0.89), 0.58 (95% CI: 0.41-0.75), respectively. The differences between AUC the ROC curves for cIVC and baseline E wave velocity, baseline VTI, baseline E/A ratio, and baseline E/Ea ratio were not statistically different ( p = 0.46, p = 0.99, p = 1.00, p = 0.26, respectively). Conclusion In spontaneously breathing patients with ACF, high cIVC values (>40%) are usually associated with fluid responsiveness while low values (< 40%) do not exclude fluid responsiveness.