Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use
Introduction To investigate whether respiratory variation of inferior vena cava diameter (cIVC) predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure (ACF). Methods Forty patients with ACF and spontaneous breathing were included. Response to fluid challenge...
Saved in:
Published in | Critical care (London, England) Vol. 16; no. 5; p. R188 |
---|---|
Main Authors | , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
London
BioMed Central
08.10.2012
BioMed Central Ltd |
Subjects | |
Online Access | Get full text |
ISSN | 1364-8535 1466-609X 1364-8535 1466-609X |
DOI | 10.1186/cc11672 |
Cover
Summary: | Introduction
To investigate whether respiratory variation of inferior vena cava diameter (cIVC) predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure (ACF).
Methods
Forty patients with ACF and spontaneous breathing were included. Response to fluid challenge was defined as a 15% increase of subaortic velocity time index (VTI) measured by transthoracic echocardiography. Inferior vena cava diameters were recorded by a subcostal view using M Mode. The cIVC was calculated as follows: (Dmax - Dmin/Dmax) × 100 and then receiver operating characteristic (ROC) curves were generated for cIVC, baseline VTI, E wave velocity, E/A and E/Ea ratios.
Results
Among 40 included patients, 20 (50%) were responders (R). The causes of ACF were sepsis (
n
= 24), haemorrhage (
n
= 11), and dehydration (
n
= 5). The area under the ROC curve for cIVC was 0.77 (95% CI: 0.60-0.88). The best cutoff value was 40% (Se = 70%, Sp = 80%). The AUC of the ROC curves for baseline E wave velocity, VTI, E/A ratio, E/Ea ratio were 0.83 (95% CI: 0.68-0.93), 0.78 (95% CI: 0.61-0.88), 0.76 (95% CI: 0.59-0.89), 0.58 (95% CI: 0.41-0.75), respectively. The differences between AUC the ROC curves for cIVC and baseline E wave velocity, baseline VTI, baseline E/A ratio, and baseline E/Ea ratio were not statistically different (
p
= 0.46,
p
= 0.99,
p
= 1.00,
p
= 0.26, respectively).
Conclusion
In spontaneously breathing patients with ACF, high cIVC values (>40%) are usually associated with fluid responsiveness while low values (< 40%) do not exclude fluid responsiveness. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 ObjectType-Undefined-3 PMCID: PMC3682290 |
ISSN: | 1364-8535 1466-609X 1364-8535 1466-609X |
DOI: | 10.1186/cc11672 |