Finding the optimal deconvolution algorithm for MR perfusion in carotid stenosis: Correlations with angiographic cerebral circulation time

The aim of our study is to explore the impacts of different deconvolution algorithms on correlations between CBF, MTT, CBV, TTP, Tmax from MR perfusion (MRP) and angiography cerebral circulation time (CCT). Retrospectively, 30 patients with unilateral carotid stenosis, and available pre-stenting MRP...

Full description

Saved in:
Bibliographic Details
Published inJournal of neuroradiology Vol. 43; no. 4; pp. 290 - 296
Main Authors Lin, Chung-Jung, Hung, Sheng-Che, Chang, Feng-Chi, Guo, Wan-Yuo, Luo, Chao-Bao, Kowarschik, Markus, Chu, Wei-Fa, Liou, Adrian J.Y. Kang
Format Journal Article
LanguageEnglish
Published France Elsevier Masson SAS 01.07.2016
Subjects
Online AccessGet full text
ISSN0150-9861
DOI10.1016/j.neurad.2016.02.002

Cover

More Information
Summary:The aim of our study is to explore the impacts of different deconvolution algorithms on correlations between CBF, MTT, CBV, TTP, Tmax from MR perfusion (MRP) and angiography cerebral circulation time (CCT). Retrospectively, 30 patients with unilateral carotid stenosis, and available pre-stenting MRP and angiography were included for analysis. All MRPs were conducted in a 1.5-T MR scanner. Standard singular value decomposition, block-circulant, and two delay-corrected algorithms were used as the deconvolution methods. All angiographies were obtained in the same bi-plane flat-detector angiographic machine. A contrast bolus of 12mL was administrated via angiocatheter at a rate of 8mL/s. The acquisition protocols were the same for all cases. CCT was defined as the difference between time to peak from the cavernous ICA and the parietal vein in lateral view. Pearson correlations were calculated for CCT and CBF, MTT, CBV, TTP, Tmax. The correlation between CCT and MTT was highest with Tmax (r=0.65), followed by MTT (r=0.60), CBF (r=−0.57), and TTP (r=0.33) when standard singular value decomposition was used. No correlation with CBV was noted. MRP using a singular value decomposition algorithm confirmed the feasibility of quantifying cerebral blood flow deficit in steno-occlusive disease within the angio-room. This approach might further improve patient safety by providing immediate cerebral hemodynamics without extraradiation and iodine contrast.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0150-9861
DOI:10.1016/j.neurad.2016.02.002