Reliability of Sonomyography for Pectoralis Major Thickness Measurement

Muscle thickness is a widely used parameter for quantifying muscle function in ultrasound imaging. However, current measurement techniques generally rely on manual digitization, which is subjective, time consuming, and prone to error. The primary purposes of this study were to develop an automated m...

Full description

Saved in:
Bibliographic Details
Published inJournal of manipulative and physiological therapeutics Vol. 33; no. 5; pp. 386 - 394
Main Authors Koo, Terry K.K., Wong, Chunwah, Zheng, Yongping
Format Journal Article
LanguageEnglish
Published United States Mosby, Inc 01.06.2010
Subjects
Online AccessGet full text
ISSN0161-4754
1532-6586
1532-6586
DOI10.1016/j.jmpt.2010.05.009

Cover

More Information
Summary:Muscle thickness is a widely used parameter for quantifying muscle function in ultrasound imaging. However, current measurement techniques generally rely on manual digitization, which is subjective, time consuming, and prone to error. The primary purposes of this study were to develop an automated muscle boundary tracking algorithm to overcome these limitations and to report its intraexaminer reliability on pectoralis major muscle. Real-time B-mode ultrasound images of the pectoralis major muscles were acquired by an integrated data acquisition system. A transducer placement protocol was developed to facilitate better repositioning of an ultrasound transducer. Intraexaminer reliability of the tracking algorithm for static measurements was studied using intraclass correlation coefficient based on the thickness data from 11 healthy subjects recruited from a chiropractic college measured at 3 independent sessions. Standard error of measurement and minimal detectable change were calculated. Feasibility of using the tracking algorithm for dynamic measurements was also evaluated. All calculated intraclass correlation coefficients were larger than 0.96, indicating excellent reliability of the sonomyographic measurements. Minimal detectable changes were 9.7%, 6.7%, and 6.8% of the muscle thickness at the lateral, central, and medial aspects, respectively. For a 400-frame image stack with 3 pairs of 40 × 40 pixels tracking windows, the tracking took about 80 seconds to complete. The tracking algorithm offers precise and reliable measurements of muscle thickness changes in clinical settings with potential to quantify the effects of a wide variety of chiropractic techniques on muscle function.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Article-2
ObjectType-Feature-1
ISSN:0161-4754
1532-6586
1532-6586
DOI:10.1016/j.jmpt.2010.05.009