Machine Learning–Based Three-Dimensional Echocardiographic Quantification of Right Ventricular Size and Function: Validation Against Cardiac Magnetic Resonance

Three-dimensional echocardiography (3DE) allows accurate and reproducible measurements of right ventricular (RV) size and function. However, widespread implementation of 3DE in routine clinical practice is limited because the existing software packages are relatively time-consuming and skill demandi...

Full description

Saved in:
Bibliographic Details
Published inJournal of the American Society of Echocardiography Vol. 32; no. 8; pp. 969 - 977
Main Authors Genovese, Davide, Rashedi, Nina, Weinert, Lynn, Narang, Akhil, Addetia, Karima, Patel, Amit R., Prater, David, Gonçalves, Alexandra, Mor-Avi, Victor, Lang, Roberto M.
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.08.2019
Subjects
Online AccessGet full text
ISSN0894-7317
1097-6795
1097-6795
DOI10.1016/j.echo.2019.04.001

Cover

More Information
Summary:Three-dimensional echocardiography (3DE) allows accurate and reproducible measurements of right ventricular (RV) size and function. However, widespread implementation of 3DE in routine clinical practice is limited because the existing software packages are relatively time-consuming and skill demanding. The aim of this study was to test the accuracy and reproducibility of new machine learning– (ML-) based, fully automated software for three-dimensional quantification of RV size and function. Fifty-six unselected patients with a wide range of RV size and function and image quality, referred for clinically indicated cardiac magnetic resonance (CMR) imaging, underwent a transthoracic 3DE exam on the same day. End-systolic and end-diastolic RV volumes (ESV, EDV) and ejection fraction (EF) were measured using the ML-based algorithm and compared with CMR reference values using Bland-Altman and linear regression analyses. RV function quantification by echocardiography was feasible in all patients. The automatic approach was accurate in 32% patients with analysis time of 15 ± 1 seconds and 100% reproducible. Endocardial contour editing was necessary after the automated postprocessing in the remaining 68% patients, prolonging analysis time to 114 ± 71 seconds. With these minimal adjustments, RV volumes and EF measurements were accurate in comparison with CMR reference (biases: EDV, −25.6 ± 21.1 mL; ESV, −7.4 ± 16 mL; EF, −3.3% ± 5.2%) and showed excellent reproducibility reflected by coefficients of variation <7% and intraclass correlations ≥0.95 for all measurements. The new ML-based 3DE algorithm provided accurate and completely reproducible RV volume and EF measurements in one-third of unselected patients without any boundary editing. In the remaining patients, quick minimal editing resulted in reasonably accurate measurements with excellent reproducibility. This approach provides a promising solution for fast three-dimensional quantification of RV size and function. •Machine-learning software for quantification of right ventricular function was tested.•Accurate, fully-automated measurements are possible in 32% of unselected patients.•With minimal editing, accurate measurements were obtained in the remaining patients.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Undefined-3
ISSN:0894-7317
1097-6795
1097-6795
DOI:10.1016/j.echo.2019.04.001