Laser speckle contrast imaging: Multifractal analysis of data recorded in healthy subjects

Purpose: The monitoring of microvascular blood flow can now be performed with laser speckle contrast imaging (LSCI), a new noninvasive laser-based technique. LSCI images have good spatial and temporal resolutions. Nevertheless, from now, few processing of these data have been performed to have a bet...

Full description

Saved in:
Bibliographic Details
Published inJournal of medical physics Vol. 39; no. 10; pp. 5849 - 5856
Main Authors Humeau-Heurtier, Anne, Mahé, Guillaume, Durand, Sylvain, Henrion, Daniel, Abraham, Pierre
Format Journal Article
LanguageEnglish
Published United States American Association of Physicists in Medicine 01.10.2012
Medknow Publications
Subjects
Online AccessGet full text
ISSN0094-2405
0971-6203
2473-4209
DOI10.1118/1.4748506

Cover

More Information
Summary:Purpose: The monitoring of microvascular blood flow can now be performed with laser speckle contrast imaging (LSCI), a new noninvasive laser-based technique. LSCI images have good spatial and temporal resolutions. Nevertheless, from now, few processing of these data have been performed to have a better knowledge on their properties. We herein propose a multifractal analysis of LSCI data recorded in the forearm of healthy subjects, based on the method from Halseyet al., one of the popular methods using the box-counting technique. Methods: In laser speckle contrast image time sequences, we studied time evolution of pixel values, as well as time evolution of pixel values averaged in regions of interest (ROI) of different sizes. The results are compared with the ones obtained with single-point laser Doppler flowmetry (LDF) signals recorded simultaneously to LSCI images. Results: Our work shows that, for the range of scales studied and with the method from Halseyet al., time evolution of pixel values present narrow multifractal spectra, reminding the ones of monofractal data. However, we observe that when LSCI pixel values are averaged in ROI large enough and followed with time, the multifractal spectra become larger and closer to the ones of LDF signals. Conclusions: Single pixels from laser speckle contrast images may not possess the same multifractal properties as LDF signals. These findings could now be compared with the ones obtained with other ranges of scales and with data recorded from pathological subjects.
Bibliography:Telephone: +33 (0)2 41 22 65 56; Fax: +33 (0)2 41 22 65 61.
Author to whom correspondence should be addressed. Electronic mail
anne.humeau@univ‐angers.fr
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0094-2405
0971-6203
2473-4209
DOI:10.1118/1.4748506