Exploring the performance of a functionalized CNT-based sensor array for breathomics through clustering and classification algorithms: from gas sensing of selective biomarkers to discrimination of chronic obstructive pulmonary disease

An array of carbon nanotube (CNT)-based sensors was produced for sensing selective biomarkers and evaluating breathomics applications with the aid of clustering and classification algorithms. We assessed the sensor array performance in identifying target volatiles and we explored the combination of...

Full description

Saved in:
Bibliographic Details
Published inRSC advances Vol. 11; no. 48; pp. 327 - 3282
Main Authors Drera, Giovanni, Freddi, Sonia, Emelianov, Aleksei V, Bobrinetskiy, Ivan I, Chiesa, Maria, Zanotti, Michele, Pagliara, Stefania, Fedorov, Fedor S, Nasibulin, Albert G, Montuschi, Paolo, Sangaletti, Luigi
Format Journal Article
LanguageEnglish
Published England Royal Society of Chemistry 10.09.2021
The Royal Society of Chemistry
Subjects
Online AccessGet full text
ISSN2046-2069
2046-2069
DOI10.1039/d1ra03337a

Cover

More Information
Summary:An array of carbon nanotube (CNT)-based sensors was produced for sensing selective biomarkers and evaluating breathomics applications with the aid of clustering and classification algorithms. We assessed the sensor array performance in identifying target volatiles and we explored the combination of various classification algorithms to analyse the results obtained from a limited dataset of exhaled breath samples. The sensor array was exposed to ammonia (NH 3 ), nitrogen dioxide (NO 2 ), hydrogen sulphide (H 2 S), and benzene (C 6 H 6 ). Among them, ammonia (NH 3 ) and nitrogen dioxide (NO 2 ) are known biomarkers of chronic obstructive pulmonary disease (COPD). Calibration curves for individual sensors in the array were obtained following exposure to the four target molecules. A remarkable response to ammonia (NH 3 ) and nitrogen dioxide (NO 2 ), according to benchmarking with available data in the literature, was observed. Sensor array responses were analyzed through principal component analysis (PCA), thus assessing the array selectivity and its capability to discriminate the four different target volatile molecules. The sensor array was then exposed to exhaled breath samples from patients affected by COPD and healthy control volunteers. A combination of PCA, supported vector machine (SVM), and linear discrimination analysis (LDA) shows that the sensor array can be trained to accurately discriminate healthy from COPD subjects, in spite of the limited dataset. Extensive application of clustering and classification algorithms shows the potential of a CNT-based sensor array in breathomics.
Bibliography:10.1039/d1ra03337a
Electronic supplementary information (ESI) available. See DOI
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:2046-2069
2046-2069
DOI:10.1039/d1ra03337a