National Survey of Radiation Doses of Pediatric Chest Radiography in Korea: Analysis of the Factors Affecting Radiation Doses

To investigate radiation doses in pediatric chest radiography in a national survey and to analyze the factors that affect radiation doses. The study was based on the results of 149 chest radiography machines in 135 hospitals nationwide. For each machine, a chest radiograph was obtained by using a ph...

Full description

Saved in:
Bibliographic Details
Published inKorean journal of radiology Vol. 13; no. 5; pp. 610 - 617
Main Authors Kim, Bo Hyun, Do, Kyung-Hyun, Goo, Hyun Woo, Yang, Dong Hyun, Oh, Sang Young, Kim, Hyeog Ju, Lee, Kwang Yong, Lee, Jung Eun
Format Journal Article
LanguageEnglish
Published Korea (South) The Korean Society of Radiology 01.09.2012
대한영상의학회
Subjects
Online AccessGet full text
ISSN1229-6929
2005-8330
2005-8330
DOI10.3348/kjr.2012.13.5.610

Cover

More Information
Summary:To investigate radiation doses in pediatric chest radiography in a national survey and to analyze the factors that affect radiation doses. The study was based on the results of 149 chest radiography machines in 135 hospitals nationwide. For each machine, a chest radiograph was obtained by using a phantom representing a 5-year-old child (ATOM® dosimetry phantom, model 705-D, CIRS, Norfolk, VA, USA) with each hospital's own protocol. Five glass dosimeters (M-GD352M, Asahi Techno Glass Corporation, Shizuoka, Japan) were horizontally installed at the center of the phantom to measure the dose. Other factors including machine's radiography system, presence of dedicated pediatric radiography machine, presence of an attending pediatric radiologist, and the use of automatic exposure control (AEC) were also evaluated. The average protocol for pediatric chest radiography examination in Korea was 94.9 peak kilovoltage and 4.30 milliampere second. The mean entrance surface dose (ESD) during a single examination was 140.4 microgray (µGy). The third quartile, median, minimum and maximum value of ESD were 160.8 µGy, 93.4 µGy, 18.8 µGy, and 2334.6 µGy, respectively. There was no significant dose difference between digital and non-digital radiography systems. The use of AEC significantly reduced radiation doses of pediatric chest radiographs (p < 0.001). Our nationwide survey shows that the third quartile, median, and mean ESD for pediatric chest radiograph is 160.8 µGy, 93.4 µGy, and 140.4 µGy, respectively. No significant dose difference is noticed between digital and non-digital radiography systems, and the use of AEC helps significantly reduce radiation doses.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
G704-001113.2012.13.5.003
ISSN:1229-6929
2005-8330
2005-8330
DOI:10.3348/kjr.2012.13.5.610