Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters

Previous studies have shown that under some conditions, noise fluctuations in an fMRI time-course are dominated by physiological modulations of the image intensity with secondary contributions from thermal image noise and that these two sources scale differently with signal intensity, susceptibility...

Full description

Saved in:
Bibliographic Details
Published inNeuroImage (Orlando, Fla.) Vol. 26; no. 1; pp. 243 - 250
Main Authors Triantafyllou, C., Hoge, R.D., Krueger, G., Wiggins, C.J., Potthast, A., Wiggins, G.C., Wald, L.L.
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 15.05.2005
Elsevier Limited
Subjects
Online AccessGet full text
ISSN1053-8119
1095-9572
DOI10.1016/j.neuroimage.2005.01.007

Cover

More Information
Summary:Previous studies have shown that under some conditions, noise fluctuations in an fMRI time-course are dominated by physiological modulations of the image intensity with secondary contributions from thermal image noise and that these two sources scale differently with signal intensity, susceptibility weighting (TE) and field strength. The SNR of the fMRI time-course was found to be near its asymptotic limit for moderate spatial resolution measurements at 3 T with only marginal gains expected from acquisition at higher field strengths. In this study, we investigate the amplitude of image intensity fluctuations in the fMRI time-course at magnetic field strengths of 1.5 T, 3 T, and 7 T as a function of image resolution, flip angle and TE. The time-course SNR was a similar function of the image SNR regardless of whether the image SNR was modulated by flip angle, image resolution, or field strength. For spatial resolutions typical of those currently used in fMRI (e.g., 3 × 3 × 3 mm 3), increases in image SNR obtained from 7 T acquisition produced only modest increases in time-course SNR. At this spatial resolution, the ratio of physiological noise to thermal image noise was 0.61, 0.89, and 2.23 for 1.5 T, 3 T, and 7 T. At a resolution of 1 × 1 × 3 mm 3, however, the physiological to thermal noise ratio was 0.34, 0.57, and 0.91 for 1.5 T, 3 T and 7 T for TE near T2*. Thus, by reducing the signal strength using higher image resolution, the ratio of physiologic to image noise could be reduced to a regime where increased sensitivity afforded by higher field strength still translated to improved SNR in the fMRI time-series.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Feature-1
content type line 23
ISSN:1053-8119
1095-9572
DOI:10.1016/j.neuroimage.2005.01.007