Free‐running 5D coronary MR angiography at 1.5T using LIBRE water excitation pulses
Purpose To implement, optimize, and characterize lipid‐insensitive binomial off‐resonant RF excitation (LIBRE) pulses for fat‐suppressed fully self‐gated free‐running 5D cardiac MRI. Methods Bloch equation simulations were used to optimize LIBRE parameter settings in non‐interrupted bSSFP prior to i...
Saved in:
Published in | Magnetic resonance in medicine Vol. 84; no. 3; pp. 1470 - 1485 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
Wiley Subscription Services, Inc
01.09.2020
|
Subjects | |
Online Access | Get full text |
ISSN | 0740-3194 1522-2594 1522-2594 |
DOI | 10.1002/mrm.28221 |
Cover
Summary: | Purpose
To implement, optimize, and characterize lipid‐insensitive binomial off‐resonant RF excitation (LIBRE) pulses for fat‐suppressed fully self‐gated free‐running 5D cardiac MRI.
Methods
Bloch equation simulations were used to optimize LIBRE parameter settings in non‐interrupted bSSFP prior to in vitro validation. Thus, optimized LIBRE pulses were subsequently applied to free‐running coronary MRA in 20 human adult subjects, where resulting images were quantitatively compared to those obtained with non‐fat‐suppressing excitation (SP), conventional 1‐2‐1 water excitation (WE), and a previously published interrupted free‐running (IFR) sequence. SAR and scan times were recorded. Respiratory‐and‐cardiac‐motion‐resolved images were reconstructed with XD‐GRASP, and contrast ratios, coronary artery detection rate, vessel length, and vessel sharpness were computed.
Results
The numerically optimized LIBRE parameters were successfully validated in vitro. In vivo, LIBRE had the lowest SAR and a scan time that was similar to that of WE yet 18% shorter than that of IFR. LIBRE improved blood–fat contrast when compared to SP, WE, and IFR, vessel detection relative to SP and IFR, and vessel sharpness when compared to WE and IFR (for example, for the left main and anterior descending coronary artery, 51.5% ± 10.2% [LIBRE] versus 42.1% ± 6.8% [IFR]). Vessel length measurements remained unchanged for all investigated methods.
Conclusion
LIBRE enabled fully self‐gated non‐interrupted free‐running 5D bSSFP imaging of the heart at 1.5T with suppressed fat signal. Measures of image quality, vessel conspicuity, and scan time compared favorably to those obtained with the more conventional non‐interrupted WE and the previously published IFR, while SAR reduction offers added flexibility. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
ISSN: | 0740-3194 1522-2594 1522-2594 |
DOI: | 10.1002/mrm.28221 |