Posture and Physical Activity Detection: Impact of Number of Sensors and Feature Type

Studies using wearable sensors to measure posture, physical activity (PA), and sedentary behavior typically use a single sensor worn on the ankle, thigh, wrist, or hip. Although the use of single sensors may be convenient, using multiple sensors is becoming more practical as sensors miniaturize. We...

Full description

Saved in:
Bibliographic Details
Published inMedicine and science in sports and exercise Vol. 52; no. 8; p. 1834
Main Authors Tang, Q U, John, Dinesh, Thapa-Chhetry, Binod, Arguello, Diego Jose, Intille, Stephen
Format Journal Article
LanguageEnglish
Published United States 01.08.2020
Subjects
Online AccessGet full text
ISSN0195-9131
1530-0315
1530-0315
DOI10.1249/MSS.0000000000002306

Cover

More Information
Summary:Studies using wearable sensors to measure posture, physical activity (PA), and sedentary behavior typically use a single sensor worn on the ankle, thigh, wrist, or hip. Although the use of single sensors may be convenient, using multiple sensors is becoming more practical as sensors miniaturize. We evaluated the effect of single-site versus multisite motion sensing at seven body locations (both ankles, wrists, hips, and dominant thigh) on the detection of physical behavior recognition using a machine learning algorithm. We also explored the effect of using orientation versus orientation-invariant features on performance. Performance (F1 score) of PA and posture recognition was evaluated using leave-one-subject-out cross-validation on a 42-participant data set containing 22 physical activities with three postures (lying, sitting, and upright). Posture and PA recognition models using two sensors had higher F1 scores (posture, 0.89 ± 0.06; PA, 0.53 ± 0.08) than did models using a single sensor (posture, 0.78 ± 0.11; PA, 0.43 ± 0.03). Models using two nonwrist sensors for posture recognition (F1 score, 0.93 ± 0.03) outperformed two-sensor models including one or two wrist sensors (F1 score, 0.85 ± 0.06). However, two-sensor models for PA recognition with at least one wrist sensor (F1 score, 0.60 ± 0.05) outperformed other two-sensor models (F1 score, 0.47 ± 0.02). Both posture and PA recognition F1 scores improved with more sensors (up to seven; 0.99 for posture and 0.70 for PA), but with diminishing performance returns. Models performed best when including orientation-based features. Researchers measuring posture should consider multisite sensing using at least two nonwrist sensors, and researchers measuring PA should consider multisite sensing using at least one wrist sensor and one nonwrist sensor. Including orientation-based features improved both posture and PA recognition.
ISSN:0195-9131
1530-0315
1530-0315
DOI:10.1249/MSS.0000000000002306