Deep learning algorithm detection of Barrett’s neoplasia with high accuracy during live endoscopic procedures: a pilot study (with video)

We assessed the preliminary diagnostic accuracy of a recently developed computer-aided detection (CAD) system for detection of Barrett’s neoplasia during live endoscopic procedures. The CAD system was tested during endoscopic procedures in 10 patients with nondysplastic Barrett’s esophagus (NDBE) an...

Full description

Saved in:
Bibliographic Details
Published inGastrointestinal endoscopy Vol. 91; no. 6; pp. 1242 - 1250
Main Authors de Groof, Albert J., Struyvenberg, Maarten R., Fockens, Kiki N., van der Putten, Joost, van der Sommen, Fons, Boers, Tim G., Zinger, Sveta, Bisschops, Raf, de With, Peter H., Pouw, Roos E., Curvers, Wouter L., Schoon, Erik J., Bergman, Jacques J.G. H.M.
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.06.2020
Subjects
Online AccessGet full text
ISSN0016-5107
1097-6779
1085-8741
1097-6779
DOI10.1016/j.gie.2019.12.048

Cover

More Information
Summary:We assessed the preliminary diagnostic accuracy of a recently developed computer-aided detection (CAD) system for detection of Barrett’s neoplasia during live endoscopic procedures. The CAD system was tested during endoscopic procedures in 10 patients with nondysplastic Barrett’s esophagus (NDBE) and 10 patients with confirmed Barrett’s neoplasia. White-light endoscopy images were obtained at every 2-cm level of the Barrett’s segment and immediately analyzed by the CAD system, providing instant feedback to the endoscopist. At every level, 3 images were evaluated by the CAD system. Outcome measures were diagnostic performance of the CAD system per level and per patient, defined as accuracy, sensitivity, and specificity (ground truth was established by expert assessment and corresponding histopathology), and concordance of 3 sequential CAD predictions per level. Accuracy, sensitivity, and specificity of the CAD system in a per-level analyses were 90%, 91%, and 89%, respectively. Nine of 10 neoplastic patients were correctly diagnosed. The single lesion not detected by CAD showed NDBE in the endoscopic resection specimen. In only 1 NDBE patient, the CAD system produced false-positive predictions. In 75% of all levels, the CAD system produced 3 concordant predictions. This is one of the first studies to evaluate a CAD system for Barrett’s neoplasia during live endoscopic procedures. The system detected neoplasia with high accuracy, with only a small number of false-positive predictions and with a high concordance rate between separate predictions. The CAD system is thereby ready for testing in larger, multicenter trials. (Clinical trial registration number: NL7544.)
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0016-5107
1097-6779
1085-8741
1097-6779
DOI:10.1016/j.gie.2019.12.048