Concurrent Validity of Four Clinical Tests Used to Measure Hamstring Flexibility

The purpose of this study was to examine the concurrent validity of 4 clinical tests used to measure hamstring muscle length. A pilot study (N = 10) was conducted to determine the intratester reliability of 4 hamstring length measuresknee extension angle (KEA), sacral angle (SA), straight leg raise...

Full description

Saved in:
Bibliographic Details
Published inJournal of strength and conditioning research Vol. 22; no. 2; pp. 583 - 588
Main Authors Davis, D Scott, Quinn, Rich O, Whiteman, Chris T, Williams, Jason D, Young, Corey R
Format Journal Article
LanguageEnglish
Published United States National Strength and Conditioning Association 01.03.2008
Lippincott Williams & Wilkins Ovid Technologies
Subjects
Online AccessGet full text
ISSN1064-8011
1533-4287
1533-4287
DOI10.1519/JSC.0b013e31816359f2

Cover

More Information
Summary:The purpose of this study was to examine the concurrent validity of 4 clinical tests used to measure hamstring muscle length. A pilot study (N = 10) was conducted to determine the intratester reliability of 4 hamstring length measuresknee extension angle (KEA), sacral angle (SA), straight leg raise (SLR), and sit and reach (SR). The pilot investigation revealed good to excellent intratester reliability (intraclass correlation coefficient = 0.92-0.95) for each of the 4 tests. Eighty-one subjects (42 men and 39 women) participated in the main investigation. Subjects were randomly tested for each of 4 assessments of hamstring length. Concurrent validity was determined using linear regression, correlation, and κ statistics. Correlation coefficients corresponding to the concurrent validity of the six combinations of the 4 clinical tests revealed poor to fair correlation (r = 0.45-0.65). The correlation coefficients for each pair from greatest to least were SR-SA= 0.65, SLR-SR = 0.65, KEA-SLR = 0.63, KEA-SR = 0.57, SLR-SA = 0.50, and KEA-SA = 0.45. Despite the common clinical use of these measures to assess hamstring length, these tests do not have sufficient concurrent validity to be used interchangeably or to assume that they each measure the same construct (hamstring length). Based on the results of this investigation and a review of the literature, the authors recommend that researchers, clinicians, and strength and conditioning specialists adopt the KEA test as the gold standard measure for hamstring muscle length.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
content type line 14
ObjectType-Feature-2
content type line 23
ObjectType-Undefined-3
ISSN:1064-8011
1533-4287
1533-4287
DOI:10.1519/JSC.0b013e31816359f2