Kinetic Curves of Malignant Lesions Are Not Consistent Across MRI Systems: Need for Improved Standardization of Breast Dynamic Contrast-Enhanced MRI Acquisition
The purpose of this study was to compare MRI kinetic curve data acquired with three systems in the evaluation of malignant lesions of the breast. The cases of 601 patients with 682 breast lesions (185 benign, 497 malignant) were selected for review. The malignant lesions were classified as ductal ca...
Saved in:
Published in | American journal of roentgenology (1976) Vol. 193; no. 3; pp. 832 - 839 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | English |
Published |
Reston, VA
Am Roentgen Ray Soc
01.09.2009
American Roentgen Ray Society |
Subjects | |
Online Access | Get full text |
ISSN | 0361-803X 1546-3141 1546-3141 |
DOI | 10.2214/AJR.08.2025 |
Cover
Summary: | The purpose of this study was to compare MRI kinetic curve data acquired with three systems in the evaluation of malignant lesions of the breast.
The cases of 601 patients with 682 breast lesions (185 benign, 497 malignant) were selected for review. The malignant lesions were classified as ductal carcinoma in situ (DCIS), invasive ductal carcinoma (IDC), and other. The dynamic MRI protocol consisted of one unenhanced and three to seven contrast-enhanced images acquired with one of three imaging protocols and systems. An experienced radiologist analyzed the shapes of the kinetic curves according to the BI-RADS lexicon. Several quantitative kinetic parameters were calculated, and the kinetic parameters of malignant lesions were compared across the three systems.
Imaging protocol and system 1 were used to image 304 malignant lesions (185 IDC, 62 DCIS); imaging protocol and system 2, 107 lesions (72 IDC, 21 DCIS); and imaging protocol and system 3, 86 lesions (64 IDC, 17 DCIS). Compared with those visualized with imaging protocols and systems 1 and 2, IDC lesions visualized with imaging protocol and system 3 had significantly less initial enhancement, longer time to peak enhancement, and a slower washout rate (p < 0.004). Only 47% of IDC lesions imaged with imaging protocol and system 3 exhibited washout type curves, compared with 75% and 74% of those imaged with imaging protocols and systems 2 and 1, respectively. The diagnostic accuracy of kinetic analysis was lowest for imaging protocol and system 3, but the difference was not statistically significant.
The kinetic curve data on malignant lesions acquired with one system showed significantly lower initial contrast uptake and a different curve shape in comparison with data acquired with the other two systems. Differences in k-space sampling, T1 weighting, and magnetization transfer effects may be explanations for the difference. |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 |
ISSN: | 0361-803X 1546-3141 1546-3141 |
DOI: | 10.2214/AJR.08.2025 |