Pre-contoured reconstruction plate fabricated via three-dimensional printed bending support

A mandibular continuity defect can be repaired using either a prosthetic device or autogenous bone. A titanium reconstruction plate can be used with a localized or vascularized flap over the defect of the mandible. Unfortunately, the plate may fail due to plate exposure, screw loosening, fracture, o...

Full description

Saved in:
Bibliographic Details
Published inJournal of the Korean Association of Oral and Maxillofacial Surgeons Vol. 47; no. 3; pp. 233 - 236
Main Authors Song, In-Seok, Ryu, Jae-Jun, Choi, Young-Jun, Lee, Ui-Lyong
Format Journal Article
LanguageEnglish
Published 대한구강악안면외과학회 30.06.2021
Korean Association Of Oral And Maxillofacial Surgeons
The Korean Association of Oral and Maxillofacial Surgeons
Subjects
Online AccessGet full text
ISSN2234-7550
2234-5930
DOI10.5125/JKAOMS.2021.47.3.233

Cover

More Information
Summary:A mandibular continuity defect can be repaired using either a prosthetic device or autogenous bone. A titanium reconstruction plate can be used with a localized or vascularized flap over the defect of the mandible. Unfortunately, the plate may fail due to plate exposure, screw loosening, fracture, or infection, and will need to be removed. Plate exposure though the skin or mucosa is one of the main reasons for failure. In the present work, the authors introduced a lingually positioned reconstruction plate fabricated via three-dimensional printed bending support. This custom reconstruction plate can avoid plate re-exposure as well as reduce surgical errors and operation time.A mandibular continuity defect can be repaired using either a prosthetic device or autogenous bone. A titanium reconstruction plate can be used with a localized or vascularized flap over the defect of the mandible. Unfortunately, the plate may fail due to plate exposure, screw loosening, fracture, or infection, and will need to be removed. Plate exposure though the skin or mucosa is one of the main reasons for failure. In the present work, the authors introduced a lingually positioned reconstruction plate fabricated via three-dimensional printed bending support. This custom reconstruction plate can avoid plate re-exposure as well as reduce surgical errors and operation time.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
KISTI1.1003/JNL.JAKO202119061992695
ISSN:2234-7550
2234-5930
DOI:10.5125/JKAOMS.2021.47.3.233