Contrast‐enhanced ultrasonography with contrast‐tuned imaging technology for the detection of prostate cancer: comparison with conventional ultrasonography

Study Type – Diagnostic (exploratory cohort) Level of Evidence 2b What's known on the subject? and What does the study add? The present study was to perform contrast‐tuned imaging (CnTI) technology to detect prostate cancer and compare the use of CnTI technology for the detection of prostate ca...

Full description

Saved in:
Bibliographic Details
Published inBJU international Vol. 109; no. 11; pp. 1620 - 1626
Main Authors Xie, Shao Wei, Li, Hong Li, Du, Jing, Xia, Jian Guo, Guo, Yi Fen, Xin, Mei, Li, Feng Hua
Format Journal Article
LanguageEnglish
Published Oxford, UK Blackwell Publishing Ltd 01.06.2012
Wiley-Blackwell
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text
ISSN1464-4096
1464-410X
1464-410X
DOI10.1111/j.1464-410X.2011.10577.x

Cover

More Information
Summary:Study Type – Diagnostic (exploratory cohort) Level of Evidence 2b What's known on the subject? and What does the study add? The present study was to perform contrast‐tuned imaging (CnTI) technology to detect prostate cancer and compare the use of CnTI technology for the detection of prostate cancer with conventional ultrasonography. The preliminary data from our study suggested that targeted biopsy of the prostate with CnTI technology could improve the cancer detection and detect higher grade prostate cancers. OBJECTIVES •  To perform contrast‐enhanced ultrasonography (CEUS) using contrast‐tuned imaging (CnTI) technology to detect prostate cancer. •  To evaluate the detection of prostate cancer with CnTI compared with conventional grey‐scale and power Doppler ultrasonography. PAIENTS AND METHODS •  In all, 150 patients referred for prostate biopsy were evaluated using transrectal grey‐scale, power Doppler and CnTI ultrasonography. •  Biopsy was performed at 10 sites in each patient. If an abnormality was found at any of these three ultrasonography examinations, a biopsy specimen was targeted towards from the corresponding site. •  The performances of the three ultrasonography techniques for prostate cancer detection were compared. RESULTS •  Prostate cancer was detected at 383 sites from 73 patients. The combination of these three examinations detected more patients with prostate cancer than grey‐scale (P= 0.002), power Doppler (P= 0.001) or baseline imaging (the combination of grey‐scale and power Doppler; P= 0.031) alone. •  By biopsy site, CnTI had higher sensitivity and accuracy (73.1% and 83.7%) than grey‐scale (50.9%; P < 0.001 and 78.8%; P < 0.001) or power Doppler (48.3%; P < 0.001 and 77.7%; P < 0.001), while the specificity was similar for grey‐scale (88.4%), power Doppler (87.8%) and CnTI (87.3%; P > 0.05 in each case). CnTI had higher sensitivity (73.1% vs 62.9%; P < 0.001), specificity (87.3% vs 82.1%; P < 0.001) and accuracy (83.7% vs 77.2%; P < 0.001) than baseline imaging. •  The mean Gleason score of CnTI‐positive cases was significantly higher than CnTI‐negative cases (7.1 vs 6.3; P= 0.002). CONCLUSIONS •  CEUS using CnTI technology enables a visualization of the microvasculature associated with prostate cancer. •  CnTI technology could be used to guide biopsy and improve the detection rate of prostate cancer. •  CnTI technology was able to detect higher grade prostate cancers.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 14
content type line 23
ISSN:1464-4096
1464-410X
1464-410X
DOI:10.1111/j.1464-410X.2011.10577.x