Using cine phase contrast magnetic resonance imaging to non-invasively study in vivo knee dynamics
We tested the accuracy and feasibility of using cine phase contrast magnetic resonance imaging (cine-PC MRI) to non-invasively measure three-dimensional, in vivo, skeletal velocity. Bone displacement was estimated by integrating the velocity measurements. Cine-PC MRI was originally developed to dire...
Saved in:
| Published in | Journal of biomechanics Vol. 31; no. 1; pp. 21 - 26 |
|---|---|
| Main Authors | , , |
| Format | Journal Article |
| Language | English |
| Published |
United States
Elsevier Ltd
01.01.1998
|
| Subjects | |
| Online Access | Get full text |
| ISSN | 0021-9290 1873-2380 |
| DOI | 10.1016/S0021-9290(97)00109-7 |
Cover
| Summary: | We tested the accuracy and feasibility of using cine phase contrast magnetic resonance imaging (cine-PC MRI) to non-invasively measure three-dimensional, in vivo, skeletal velocity. Bone displacement was estimated by integrating the velocity measurements. Cine-PC MRI was originally developed to directly and non-invasively measure in vivo blood and heart velocity. Since no standard of reference exists for in vivo measurement of trabecular bone motion, a motion phantom (consisting of a series of paired gears that moved a sample box containing a human femoral bone sample) was built to assess the accuracy of tracking trabecular bone with cine-PC MRI. The in-plane, average absolute displacement errors were 0.55±0.38 and 0.36±0.27
mm in the
x- and
y-direction, respectively. Thus, estimates of bone position based on the integration of bone velocity measurements are affected little by the magnetic properties of bone [
Majumdar and Genant (1995) Osteoporos International 5, 79–92]. The velocity profiles of the patella, femur and tibia were measured in five healthy subjects during leg extensions. Extension was resisted by a 34
N weight. Subjects maintained a consistent motion rate (35±0.5
cycles
min
-1) and motion artifacts were minimal. Our results indicate that patellar flexion lags knee flexion and the patella tilts laterally and then medially as the knee extends. We conclude cine-PC MRI is a promising technique for the non-invasive measurement of in vivo skeletal dynamics and, based on our previous work, muscular dynamics as well. |
|---|---|
| Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 ObjectType-Article-1 ObjectType-Feature-2 |
| ISSN: | 0021-9290 1873-2380 |
| DOI: | 10.1016/S0021-9290(97)00109-7 |